Electrical installation
KLS2
-X120/
21
DC +24 V Supply voltage OUT 2 (power
supply unit modules 2)
–F121
–F123
–F125
-X120/
23
DC +24 V
-X120/
25
DC +24 V
-X120/
22
GND
Ground 2
-X120/
24
GND
-X120/
26
GND
-X120/
27
Shield
Shield
–
-X120/
28
Shield
-X120/
29
Shield
Tab. 20 MSC800-3400: assignment of the -X120 terminal block, part 2 for
supply voltage OUT 2 on ICR890 (system 2)
Terminal
Signal
Function
Protected by fuse
-X120/
41
+
Measuring point thermal circuit breaker 1
(red)
1)
–
-X120/
42
–
Measuring point thermal circuit breaker 1
(red)
1)
–
-X120/
51
DC +24 V Supply voltage OUT 1
(power supply unit module 1, tap before circuit
breaker F111/113/115) on thermal circuit
breaker 2 (blue)/fan 1 and 2
F1 (4 A, slow-acting)
-X120/
52
GND
Ground
–
1)
Thermal circuit breaker, left in the MSC800-3400 (see
on page 22), switch
opens at T
U
= 57.5 °C.
By setting up a closed circuit (DC +24 V on terminal -X120/41; GND on terminal -X120/42) and using
appropriate assessment, e.g., by the logic unit of an MSC800, it is possible to signal overheating of the
cabinet. It is also possible to use series connection of the same thermal circuit breaker to MSC800 cabinets
of the same type.
2)
Thermal circuit breaker, right in the MSC800-3400 (see
closes at T
U
= 37.5 °C and switches the two fans on/off.
Tab. 21 MSC800-3400: assignment of the -X120 terminal block, part 3 for
supply voltage OUT 1 on thermal circuit breaker/fan