Chapter
5
MSC800
46
Operating instructions | SICK
8011540/14B8/2019-06-06
Subject to change without notice
Electrical installation
MSC800-2100
Fig. 18: Terminals on the MSC800-2100 for mains voltage IN and supply voltage OUT
Connections for mains voltage IN on the MSC800-2100
Terminal
Color
Signal
Function
-X100/1.
1
Gray
L
Mains voltage AC 100 ... 264 V / 50 ... 60 Hz (phase)
-X100/1.
4
Blue
N
Mains voltage AC 100 ... 264 V / 50 ... 60 Hz (neutral
conductor)
-X100/1.
6
Green-yellow PE
Protective conductor
-X100/1.
7
Green-yellow PE
Tab. 13: MSC800-2100: -X100 terminal block pin assignment for mains voltage IN
Connections for supply voltage OUT
Terminal
Signal
Function
Protected by fuse
11+
DC +24 V
Supply voltage OUT
F1 (4 A, slow-acting)
12+
DC +24 V
Supply voltage OUT
F2 (4 A, slow-acting)
13+
DC +24 V
Supply voltage OUT
F3 (4 A, slow-acting)
14+
DC +24 V
Supply voltage OUT
F4 (4 A, slow-acting)
15+
DC +24 V
Supply voltage OUT
F5 (4 A, slow-acting)
16+
DC +24 V
Supply voltage OUT
F6 (2 A, slow-acting)
21–/22–/23–/
24–/25–/26–
GND
Ground
Tab. 14 MSC800-2100: assignment of the 12-pin terminal block for
supply voltage OUT on CLV490, VMS4xx/5xx, and logic unit of the MSC800