The sensor detects the movement stops and then assigns the respective switching points to the found positions.
(Taking into account the set switching point width, the positions must be at least 1 mm apart to be detected as two
different positions).
The initial position of the piston when
Dynamic Teach
starts is NOT seen as the first stop!
NOTE
The magnet must be moved at a speed greater than 0.025 m/s so the
Dynamic Teach
works correctly.
OPERATION
8
8025942/2020-07-16 | SICK
O P E R A T I N G I N S T R U C T I O N S | MPS-G with 2 / 3 switching points and IO-Link (up to 16 switching points)