Page 2: ...his document is protected by copyright The SICK AG company retains this right Reproducing this document in whole or part is only permissible within the limits of the statutory regulations of copyright...

Page 3: ...2 Mounting alternatives 5 2 3 Mounting on the rear of the press crosshead 7 2 3 1 Premounting vertical adjusting arms on the left right 7 2 3 2 Premounting horizontal adjusting arms on the left right...

Page 4: ...sensor rapidly in case of frequent tool changes 1 1 Scope of delivery The SICK mounting kit 2 is supplied in two packages One package contains all the components required to mount the retaining device...

Page 5: ...ys sizes 4 6 10 Side cutting pliers Thread cutter M12 or M8 for mounting without horizontal adjusting arm 2 2 Mounting alternatives Depending on the nature of the press there are two mounting alternat...

Page 6: ...ved 8 011 148 14 04 05 Mounting Mounting on the side of the press crosshead If the press crosshead has sufficient depth mounting on the side of the press crosshead with one adjusting arm each is possi...

Page 7: ...djusting arm has to be modified Position the adjusting arm 1 so that the scale 2 faces to the front and the cable outlet opening 7 faces to the rear For the right hand mounting side remove the adapter...

Page 8: ...the cross adapter with spring washers and screws in the sliding nuts 2 Tighten the screws hand tight so that the cross adapter can still be moved later Put the cover 3 on the adjusting arm 2 3 3 Mount...

Page 9: ...sshead Tighten the screws 2 3 4 Mounting vertical adjusting arms in the cross adapter Mounting the vertical adjusting arm on the left Mount the clamping lever 3 to the cross adapter 1 Screw the stop b...

Page 10: ...justing arm Mounting the vertical adjusting arm on the right Carry out mounting as for the left 2 3 5 Applying latching marks Latching marks can be applied at the vertical adjusting arm in order to tr...

Page 11: ...ch on the left and right hand sides of the adapter plate 3 Loosen the 4th screw Turn the adapter plate by 180 On the receiver end insert the cable ends 3 cables together from above into the adjusting...

Page 12: ...o the adjusting arm Repeat the procedure on the sender end Insert the cables and attach the cable protection Bend the cable protection tube 2 at both adjusting arms and slide it into the cable outlet...

Page 13: ...7 Screw the clamping lever 5 to the cross adapter 1 Screw the stop bolt 3 and spacer ring 2 into the centre thread and tighten it According to the dimensional drawing drill holes 6 8 mm in diameter an...

Page 14: ...e Phone 47 67 81 50 00 E Mail austefjord sick no s t e r r e i c h Phone 43 0 22 36 62 28 8 0 E Mail office sick at P o l s k a Phone 48 22 837 40 50 E Mail info sick pl R e p u b l i k a S l o w e n...