Data transmission rate
■
COM2: 38.4 kbit/s
■
COM3: 230.4 kbit/s
Maximum length of cable
20 m
Cycle time
•
MLG-2 Pro
•
14 ms
Vendor ID
26
Device ID
•
MLG-2 Pro
•
8388712
Process data
•
MLG-2 Pro
•
32 bytes (TYPE_2_V)
1
Table 49: MLG-2 data sheet - IO-Link interface
1
For an IO-Link master with V1.0, reverts to interleaved mode (consisting of TYPE_1_1 (process data) and
TYPE_1_2 (on-request data)).
Technical measurement data
Wavelength
850 nm
Ambient light immunity
•
Standard operating mode
•
Sunlight-resistant operating mode
1
•
150,000 lx (constant light, indirect)
•
150,000 lx (constant light, direct and indirect)
Minimum detectable object for devices
with 5 mm, 10 mm, 20 mm, 25 mm,
30 mm, 50 mm beam separation
•
With normal measurement accu‐
racy
•
With high measurement accuracy
•
In Transparent operating mode
•
In Sunlight-resistant operating
mode
•
Cross beam function
•
Beam sepa 4 mm
•
Beam separation
•
Beam separation
2
•
Beam sepa 4 mm
.
•
0.5 × beam sepa 4 mm
Minimum detectable object for devices
with 2.5 mm beam separation
•
With normal measurement accu‐
racy
•
In Sunlight-resistant operating
mode
•
With high measurement accuracy
•
In Transparent operating mode
•
Cross beam function
•
Beam sepa 1 mm
•
Beam sepa 1.5 mm
.
•
Beam separation
•
Beam separation
3
•
0.2 × beam sepa 3.5 mm
Beam separation
2.5 mm, 5 mm, 10 mm, 20 mm, 25 mm, 30 mm,
50 mm
Number of beams
6 … 510
Detection height
130 … 3140 mm
Limiting range
2.8 m/7 m/12 m depending on device type
4
Operating range
2 m/5 m/8.560 m depending on device type
5
Minimum sensing range
•
With parallel-beam function
•
With cross-beam function
•
0 mm
•
)
Initialization time after switch-on
< 1 s
Table 50: MLG-2 data sheet - technical measurement specifications
TECHNICAL DATA
13
8017460.ZIK1/2017-02-13 | SICK
O P E R A T I N G I N S T R U C T I O N S | MLG-2 Pro
121
Subject to change without notice