Name
Use
Data type
Definition
Values
Safety implica‐
tion
SafeCutOffPath01
BOOL
Cut-off path 01 (safety-
oriented)
The signal is ON if
the currently monitored
field in the cut-off path
is safety-related and
free.
0 = OFF state,
protective field
interrupted
Safety-relevant
parameter
1 = ON state,
protective field
free
SafeCutOffPath02
…
SafeCutOffPath08
BOOL
Cut-off path 02 … 08
(safety-oriented)
The signal is ON if
the currently monitored
field in the cut-off path
is safety-related and
free.
1)
0 = OFF state,
protective field
interrupted
Safety-relevant
parameter
1 = ON state,
protective field
free
Speed1
INT
Speed at dynamic con‐
trol input 1
-32000 ...
+32000 = speed
in mm/s
Safety-relevant
parameter
Speed1Valid
BOOL
Speed1 valid
0 = Invalid speed Safety-relevant
parameter
1 = speed valid
Speed2
INT
Speed at dynamic con‐
trol input 2
-32000 ...
+32000 = speed
in mm/s
Safety-relevant
parameter
Speed2Valid
BOOL
Speed2 valid
0 = Invalid speed Safety-relevant
parameter
1 = speed valid
StandbymodeActive
Diagnostics
BOOL
Status sleep mode
Signals whether the
device is in sleep
mode.
0 = device not in
sleep mode
Parameter with‐
out safety impli‐
cation
1 = device in
sleep mode
1)
Cut-off paths 5 to 8 are only available for the Pro performance package.
13.7.1.2
Content of the assemblies
13.7.1.2.1
Assembly 103: input of the device, output of the control
•
CIP Safety
•
Update cycle: 5 ms (or a multiple of this, depending on RPI)
•
Length: 16 bytes
•
Switching between monitoring cases via monitoring case number
Table 44: Assembly 103
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Reserved
ActivateS‐
tandbyMode
StopAlarm‐
Detection
Reserved
TriggerRun‐
Mode
1
SetMonitoringCaseNoTable1
2
SetMonitoringCaseNoTable2
3
SetMonitoringCaseNoTable3
4
SetMonitoringCaseNoTable4
5
Reserved
6
Reserved
7
Reserved
8
Reserved
TECHNICAL DATA
13
8025424/1ELL/2022-01-21 | SICK
O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O
199
Subject to change without notice