microScan3 Pro I/O
Sinusoidal vibrations
•
50 m/s², 0.35 mm, 10 Hz … 150 Hz
•
5 m/s², 1.5 mm, 5 Hz … 200 Hz
•
10 m/s², 3.5 mm, 5 Hz … 150 Hz
Noise vibrations
•
0.5 m²/s³, 5 Hz … 200 Hz
•
0.1 m²/s³, 200 Hz … 500 Hz
Shock resistance
4)
Standards
•
IEC 60068-2-27
•
IEC 60721-3-5
•
IEC TR 60721-4-3
•
IEC 61496-1
•
IEC 61496-3
Class
•
5M1 (IEC 60721-3-5)
•
3M4 (IEC TR 60721-4-3)
Single shock
50 m/s², 11 ms
Continuous shock
•
100 m/s², 16 ms
•
150 m/s², 6 ms
EMC
In accordance with IEC 61496-1, IEC 61000-6-2, and
IEC 61000-6-4
1)
The specified enclosure rating is only valid if the safety laser scanner is closed, the system plug is
mounted, and all of the M12 plug connectors of the safety laser scanner have been closed using a cable
plug connector or using a protective cap.
2)
For ambient light sources directly in the scan plane in accordance with IEC 61496-3: ≤ 3 klx.
3)
IEC 61496-1, no. 4.3.1 and no. 5.4.2, IEC 61496-3, no. 4.3.1 and no. 5.4.2. Condensation has an
influence on normal operation.
4)
For direct mounting.
Miscellaneous data
Table 37: Miscellaneous data
microScan3 Pro I/O
Wavelength
845 nm
Detectable remission
1.8% … several 1,000%
Maximum uniform contami‐
nation of the optics cover
without reducing the detec‐
tion capability
1)
30%
Area where detection capabil‐
ity is restricted
≤ 50 mm
2)
Light spot size
3)
Devices with a max. protective field range of 4.0 m
At front screen 18 mm × 4 mm
At 4.0 m distance 5 mm × 11 mm
At 5.5 m distance 2 mm × 18 mm
At 9.0 m distance 11 mm × 27 mm
Devices with max. protective field range 5.5 m
At front screen 18 mm × 4 mm
At 4.0 m distance 5 mm × 11 mm
At 5.5 m distance 2 mm × 18 mm
At 9.0 m distance 11 mm × 27 mm
Devices with max. protective field range 9.0 m
TECHNICAL DATA
13
8025424/1ELL/2022-01-21 | SICK
O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O
185
Subject to change without notice