10
Technical data
10.1
Analog MAX48
Table 17: Technical specifications
Performance
Measurand
Position
Measuring range
0050 … 2,500 mm (in 1 mm steps)
Unusable measuring range:
Null zone (zero point)
30.0 mm
Damping (end point)
30.0 mm/ 36.0 mm/ 63.0 mm (depending on type)
Power-up delay
< 250 msec
Measuring frequency (internal)
2 ms
Setpoint tolerance
Zero and end point of the usable piston stroke
≤ 1.0 mm
Resolution
0.1 mm typical (noise-free)
Hysteresis
± 0.1 mm
Linearity
± 0.25 mm of measuring range up to 500 mm (typical)
± 0.04% F.S. of measuring range above 500 mm (typical)
Temperature drift (warm-up phase)
max. ± 0.25 mm
Interface
Electrical interface
Analog
Voltage signal
0.25 … 4.75 VDC
0.50 … 4.50 VDC
0.50 … 9.50 VDC
1.00 … 9.00 VDC
Current signal
4 … 20 mA
Electrical connection
M12 male connector
4-pin, wire length
060 … 240 mm (depending on type)
3-wire cable
3 x 0.32 mm² (AWG22),
stripped 300 … 10,000 mm (depending on type)
Electrical data
Supply voltage
12 VDC (8 ... 16 VDC)
24 VDC (8 ... 30 VDC)
Supply voltage ripple
< 1% p-p
Power consumption:
12 VDC voltage signal
≤ 0.5 W
24 VDC voltage signal
≤ 0.5 W
24 VDC current signal
≤ 1.0 W
Current consumption:
12 VDC voltage signal
≤ 30 mA
24 VDC voltage signal
≤ 20 mA
24 VDC current signal
≤ 40 mA
Load resistance:
Voltage signal
RL ≥ 10 kΩ
10