Chapter
8
Operating Instructions
M4000 Adv., Adv. A/P, Area
82
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
8010797/YT72/2016-02-19
Subject to change without notice
Electrical installation
8.1
System connection M26 × 11 + FE
8.1.1
M4000 Advanced or M4000 Advanced A/P
Pin Wire colour
Sender
Receiver or
M4000 Advanced A/P
1
Brown
Input 24 V DC (voltage
supply)
Input 24 V DC (voltage supply)
2
Blue
0 V DC (voltage supply)
0 V DC (voltage supply)
3
Grey Test
input:
0 V: external test active
24 V: external test inactive
OSSD1 (output signal switching device
1)
4
Pink
Reserved
OSSD2 (output signal switching device
2)
5
Red Reserved
Reset/restart
or
Reset/override (combined)
6
Yellow
Reserved
External device monitoring (EDM)
7
White
Reserved
Application diagnostic output (ADO)
8
Red/blue Reserved
Reset
required
9
Black Device
communication
(EFI
A
)
Device communication (EFI
A
)
10 Purple Device
communication
(EFI
B
)
Device communication (EFI
B
)
11 Grey/pink Reserved
Belt stop/C1 (only in conjunction with
UE403 or sens:Control device)
FE Green
Functional earth
Functional earth
For the connection of pin 9 and 10 only use cable with twisted cores, e.g. the SICK con-
nection cables available as accessories (see section 14.7 “Accessories” on page 139).
If the UE403 safety relay is used on the extension connection of the M4000, then only
SICK sens:Control devices may be connected to pin 9 and pin 10 (EFI device
communication) of the system connection.
If you do not use either a UE403 or a sens:Control device on the system connection
pin 9 and 10 (EFI device communication), to improve the EMC behaviour we recom-
6)
It is only possible to connect
Reset/Override (combined)
on the M4000 in conjunction with an UE403 or
sens:Control device.
Fig. 51: Pin assignment
system connection M4000
Advanced or M4000
Advanced A/P M26 × 11 + FE
Tab. 32: Pin assignment
system connection
M4000 Advanced or
M4000 Advanced A/P
M26 × 11 + FE
Notes
1
2
9
3
4
10
5
6
11
7
8
FE
1
2
9
3
4
10
5
6
11
7
8
FE