NOTE: Anchors are sensitive to RF electromagnetic fields in the 
ranges 950±20 MHz and 1900±50 MHz. Performance can be 
affected  on  exposure  of  anchor.  To  avoid  that,  it’s 
recommended that minimum distance to DECT base station is 
2 m and a minimum distance to UHF RFID readers is 1 m. 
Only use shielded cables (CAT6 or higher) that are grounded 
properly. Maximum cable length is 100 m for PoE from anchor 
to PoE switch.  
NOTE:  Anchors  needs  to  be  connected  to  a  physically 
separated  network,  separate  VLAN  or  firewall  protected 
network,  due  to  security  reasons  and  also  to  get  the  best 
performance and have easier management. High traffic due to 
the  localization  system  could  cause  issues  /  slow  down  the 
network if the anchors are in the same network as other critical 
infrastructure. 

 

Figure 1. Dimensions of LOCU 212-503  

 

Figure 2. Dimensions of LOCU 200-003  

 

 

 

Power over Ethernet 

Connect  anchor  to  network  switch  supporting  PoE  IEEE 

802.3af standard with Ethernet CAT6 cable.  
Once the anchor is connected to a stable power supply, a blue 
LED blinks several times that indicates the anchor was turned 

ON. Then LED is turned OFF. 

 

DC 48 V, Passive PoE 

Anchor can be also powered from single or multiple port PoE 
injector  with  DC  48V  output.  Power  supply  is  injected  and 
delivered  into  unused  Ethernet  pairs  (Pairs  4,5  positive 

terminal and 7,8 negative terminal). 

 

NOTE:

 

Always  use  galvanic  isolated  48V  power  adaptor  with 

short circuit protection for passive PoE injection. Never connect 
“Power+Data” injector ports to the computer or other network 
devices. 

 

 

 

To  get  the  best  anchor  performance  it  is  recommended  to 
deploy all anchors to the same hight in a given localization 
area  and  anchor  position  in  the  area  should  follow  square 
geometry with distance between each anchor from 5-15 m. 
The ratio between the two sides of the square should not be 
higher than 3:1. 
If possible, always maintain a direct Line of Sight between 
the tag and the anchors.
 
For narrow corridors zig-zag positioning is an option. This can 
be very useful in narrow corridors, for example in large 
warehouses. Be aware that this deployment decreases 
precision in the Y axis, so use this option as a last resort: 

 
 

 

Figure 3. Square geometry deployment (left) Zig-Zag deployment 

(right) 

Anchors  are  typically  deployed  at  the  height  3  –  6  meters 
above  the  floor.  Recommended  mounting  is with  SICK  wall 
mount  bracket  and  holder,  available  as  accessory.  Mount 
LOCU 200-003 with the antenna pointing downwards in order 
to get maximum possible performance. 

 

NOTE:  Keep  a  distance  from  anchor  to  any  walls  or  metall 
parts of at least 15 cm in all directions to avoid significant 
degradation of performance.  

 

 

 

 

 

LOCU 212-503 

LOCU 200-003 

Size 

212 x 190 x 36 mm 

74 x 74 x 25 mm 

Weight 

390 g 

72 g 

Power supply 

PoE 802.3af or DC 48V (passive PoE) 

Power 

requirements 

2.5 W 

Operating 

conditions 

-20° – 60°C 

20-85 % humidity 

Warm-up time 

Immediate 

Sensors 

Barometer 

Placement 

Indoor 

UWB antenna 

Directional CH5 

Omnidirectional CH5 

UWB Radiated 

power 

Channel 5, Band: 6240 MHz – 6739.2 MHz 

Center Frequency: 6489.6 MHz 
-41,3 dBm/MHz 

 

Step 1: Power supply options

 

 

Technical data  

 

 

Step 2: Mounting

 

 