: Scan display (left-hand side) and buttons for finalizing device configura‐
tion.
NOTE
Changes to parameters that are made in SOPAS ET are not saved automatically in
the device. After you have completed the configuration, you must save it in the
device permanently by pressing the
Save permanently
button.
7.2
Output of measured values via terminal program
Example commands for output of measured values
If the LMS4000 sensor receives one of the two example commands by telegram via the
Ethernet interface, it will start the output of measured values via this data interface.
The device must be switched on and in measuring mode.
The detailed structure of the output telegram as well as the flow of requests and out‐
puts is described in the “Measurement output telegram” chapter in the Telegram listing
publication (English, no. 8014631).
Request for output of measured values:
Table 7: Telegram structure: sRN LMDscandata
Telegram part
Description
Variable type
Length (Byte)
Value range
Command type
Request (SOPAS
read by name)
string
3
sRN
Command
Request data
string
11
LMDscandata
Table 8: Example:
sRN LMDscandata
Telegram type
Command
CoLa A
ASCII
<STX>sRN{SPC}LMDscandata<ETX>
HEX
02 73 52 4E 20 4C 4D 44 73 63 61 6E 64 61 74 61 03
CoLa B Binary
02 02 02 02 00 00 00 0F 73 52 4E 20 4C 4D 44 73 63 61
6E 64 61 74 61 05
Request for continuous output of measured values:
7
OPERATION
38
O P E R A T I N G I N S T R U C T I O N S | LMS4000
8023198//2018-06-18 | SICK
Subject to change without notice