ONLINE HELP SOPAS
Chapter
5
LECTOR®620
Parameters
8013778/Y269/2013-11-27
©
SICK AG · Germany · All rights reserved · Subject to change without notice
25
5
Parameters
Settings for protecting the configuration can be made on the
tab.
The P
ARAMETER
folder in the project tree combines all available parameters.
5.1
General
Password protection for the device configuration can be activated in the
group.
Password protection ensures that only authorized users can enter device parameters. This
prevents incorrect settings from being made.
5.1.1
Configuration is password protected
If this parameter is activated, access to the device configuration is password protected. To
be able to change parameters, you must log in to the device at the user level of authorized
customer or higher. You can use the SOPAS options, which can be found outside of the de-
vice configuration, without logging in. Password protection is activated the next time the de-
vice is restarted.
5.2
Auto setup via function button menu
The
Auto setup via function button menu
group contains the parameters for adjusting the
auto-setup wizards.
The A
UTO
-S
ETUP
function is divided into three individual modules:
• R
EADING
DISTANCE
• I
MAGE
SETTINGS
(brightness and contrast)
• C
ODE
SETTINGS
(currently only available for D
ATA
M
ATRIX
)
The A
UTO
-S
ETUP
function can be started in different ways:
• via wizard
• via the pushbuttons on LECTOR
®
620
• by pressing the A
UTO
buttons
• via command (SOPAS command)
Commands for starting the A
UTO
-S
ETUP
function:
•
S
MN
M
ASS
TART
: The Auto-Setup process is started.
•
S
MN
M
ASF
INISH
: The Auto-Setup process is stopped and the result is transmitted. To re-
turn to reading mode, you must end the Auto-Setup process with a stop command.
•
S
MN
M
ASC
ANCEL
: The Auto-Setup process is stopped. This does, however, cause the result
to be discarded. To return to reading mode, you must end the Auto-Setup process with a
stop command.
Even if you start the A
UTO
-S
ETUP
function via a command, the settings for the wizard
(standard or advanced) are taken into consideration. The settings can also be configured
using commands. A detailed list of commands can be obtained from SICK on request.