Parameters
5.10.13 Digital outputs/Beeper
tab contains all of the parameters for configuring the digital out-
puts.
These parameters define which events cause an output signal to be sent.
The required output signal function must be configured accordingly in another area. The
use of output signals as object triggers, for example, is set on the
tab.
5.10.13.1 Output / Result 1
The
group contains the parameters for modifying digital output 1.
5.10.13.1.1
Active
The
parameter is used to select the event for which the digital output is activated.
• SOPAS C
OMMAND
: The output is activated by a command. As a result, the defined statuses
can be displayed via a connected control lamp as a result of a controller (PLC) command.
• D
EVICE
READY
: The output is activated as soon as the LECTOR
®
620 is operational.
• G
OOD
R
EAD
: The output is activated in the event of a successful reading.
• N
O
R
EAD
: The output is activated in the event of an unsuccessful reading.
• T
EACH
-
IN
1 OK: The output is activated if the M
ATCHCODE
T
EACH
-
IN
1 was taught in suc-
cessfully.
• T
EACH
-
IN
1 NOK: The output is activated if the M
ATCHCODE
T
EACH
-
IN
1 was not taught in suc-
cessfully.
• T
EACH
-
IN
2 OK: The output is activated if the M
ATCHCODE
T
EACH
-
IN
2 was taught in suc-
cessfully.
• T
EACH
-
IN
2 NOK: The output is activated if the M
ATCHCODE
T
EACH
-
IN
2 was not taught in suc-
cessfully.
• C
ONDITION
M
ATCH
1: The output is activated if the read code corresponds to the matchcode
from C
ONDITION
M
ATCH
1.
• C
ONDITION
M
ULT
C
ODES
1: The output is activated if the number of read codes corresponds
to the required number from C
ONDITION
M
ULT
C
ODES
1.
• C
ONDITION
T
EACH
I
N
1: The output is activated if the read code corresponds to the match-
code from C
ONDITION
T
EACH
I
N
1.
• C
ONDITION
T
EACH
I
N
2: The output is activated if the read code corresponds to the match-
code from C
ONDITION
T
EACH
I
N
2.
5.10.13.1.2
Function (Off)
parameter is used to select the event for which the digital output is deac-
tivated.
• T
IMER
/T
RACKING
: The output is deactivated after a certain period of time (
• N
EXT
OBJECT
TRIGGER
: The output is deactivated as soon as the next reading gate is opened.
• SOPAS C
OMMAND
: The output is deactivated by a command. As a result, the defined sta-
tuses can be displayed via a connected control lamp as a result of a controller (PLC) com-
mand.