COMMISSIONING AND OPERATION
5
8024534 / / 2019-08-19
Operating Instructions | InspectorP Rack Fine Positioning
21
User levels
Password
Application
•
Adjust the device optimally to the circumstances.
•
Deep understanding of the application necessary.
•
Suited for fine adjustment during initial commissioning.
All other user levels have no effect on the application and can be ignored. The higher
the user level, the more parameters are available, making it possible to make detailed
settings on the device.
SOPASair opens in the
Run
user level by default. Using the
Operator
or
Maintenance
user level is recommended for initial commissioning.
Adjusting language
The language of the user interface can be adapted in the
Settings
window.
Loading default
If the device has already been parameterized for an application, then first load the de-
fault:
1.
Switch to the
Maintenance
user level.
2.
Open the
Advanced Setup
window.
3.
Click on the
Restore all default parameters
button at the very bottom in the pa-
rameter bar.
5.3.3
Fine adjustment of the device
After the device has been roughly aligned during mounting, fine adjustment is done us-
ing the SOPASair operating software.
Prerequisites
•
The device has been mounted at the same height as the positioning mark.
•
The device is aligned vertically to the rack with a view to the positioning mark.
•
The
Operator
or
Maintenance
user level is set.
1.
Open the
Operation
window in SOPASair.
2.
Activate the
Continuous measurement
and
Display Image
switches.
The device begins recording and evaluating images and transmits the im-
ages to the PC.
3.
Finely adjust the device mechanically using the image so that the following factors
exist:
−
The positioning mark (red) is located within the target region (green).
−
Use of holes: The image is lit up so that the light-colored light spot can be
seen uniformly around the dark hole.
−
Use of reflectors: The image is lit up so that the light reflector is clearly identi-
fiable compared to the dark background.
If the positioning mark is located in the target region, the feedback LED of
the device lights up green.
The circle in the center is green in the
Digital Output
area. The surrounding
squares are black. The current position of the positioning mark is therefore
located within the target region.