Operating Instructions
Symbology Reading Control
IDM corded & IDM Bluetooth
8017159/2014-04-24
© SICK AG · Germany · All rights reserved · Subject to change without notice
49
3.7.7
UPC-A/ UPC-E
PROGRAM
F_DEFAULT
Family Code Selection
P.C.
Parameter Selection
Option Code
UPC-A Family Settings
SS Disable UPC-A
0
SS Enable UPC-A
1
SS Disable UPC-E
2
SS Enable UPC-E
3
SS Disable UPC-E expansion
4
SS Enable UPC-E expansion
5
SS Disable UPC standardization
6
SS Enable UPC standardization
7
SS Disable UPC numeric system
8
SS Enable UPC numeric system
9
SS Disable UPC-A check digit transmission
A
SS Enable UPC-A check digit transmission
B
SS Disable UPC-E check digit transmission
C
SS Enable UPC-E check digit transmission
D
SS Disable UPC “leading 1” portion
E
SS Enable UPC “leading 1” portion
F
When enable UPC-E expansion, the UPC-E decoded data will be converted to UPC-A format and
affected by related settings, such as UPC standardization, UPC numeric system and UPC-A check digit
transmission.
UPC-E & EAN-8 Expansion:
Expand the 8-digit UPC-E and 8-digit ENA-8 to 12-digit UPC-A and 13-digit EAN-13.
UPC-A Standardization:
Expand the 12-digit UPC-A to 13-digit EAN-13 with 1 zero insertion.
UPC Lead 1 Numeric System:
To read UPC leading with the 1 numeric system, you must enable this option.
WPC Selection
(UPC/EAN/CAN)
Basic
Length
Disable
Check
Digit
Disable
Numeric
System
With 2-digit
Addendum
With 5-digit
Addendum
Enable
Standardization
Enable
Expansion
UPC-A
12
- 1
- 1
+ 2
+ 5
+ 1
0
UPC-E
8
- 1
- 1
+ 2
+ 5
+ 1
+ 4
EAN-13
13
- 1
NC
+ 2
+ 5
NC
0
EAN-8
8
- 1
NC
+ 2
+ 5
NC
+ 5