Extensions for connection modules
Part No.
Type
Description
Design
1 023 850
CMC 400-101
Parameter memory (Connection Module Cloning) as plug-in module for
the
CDB 420
or
CDM 420
Connection Module.
Storage of parameter set for ICR 84x (from firmware version V 1.95).
Rotary code switches for activating the network mode of the ICR 84x.
Operating temperature 0 to +40
°
C (+32 to +104
°
F), operating
voltage 10 to 30 V DC via CDB 420 or CDM 420, power consumption
0.5 W.
2 029 466
CDM 400
Display module (Connection Display Module), 4 x 20 digits (LCD) with
keyboard in optional cover for the
CDM 420
Connection Module.
Representation of reading results, reading diagnosis data and
messages from the ICR 84x (from firmware version V 1.95).
Connection to the CDM 420 via ribbon cable. Operating temperature 0
to +40
°
C (+32 to +104
°
F), operating voltage
18
to 30 V DC via
CDM 420, power consumption 1 W.
Prerequisite: CMC 400-101 parameter memory for controlling the
display.
2 029 468
CMP 400
Power Supply Module (Connection Module Power) as plug-in module
for the
CDM 420
Connection Module.
Power supply for ICR 84x from an AC power line.
Input 100 to 250 V AC/50 to 60 Hz, output 24 V DC, max. 10.8 W
(short-circuit proof).
Connection to the CDM 420 via ribbon cable.
Operating temperature 0 to +40
°
C (+32 to +104
°
F).
1 026 241
CMF 400-1001
Field bus gateway (Connection Module Fieldbus) as plug-in module for
the
CDM 420
Connection Module.
For connecting one ICR 84x (from firmware version V 1.95) to
Profibus-DP
(Slave) via RS 232 data interface.
With 9-pin D Sub
socket on front panel for bus connection (enclosure rating IP 20) and
5-core
terminal strip for connecting 2 digital inputs and 2 digital outputs.
Connection to the CDM 420 via connector, operating temperature
0 to +40
°
C (+32 to +104
°
F), operating voltage
18
to 30 V DC via
CDM 420, power consumption 2 W.
1 026 643
CMF 400-1101
as CMF 400-1001, but enclosure rating max. IP 65
–
1 026 242
CMF 400-2101
Field bus gateway (Connection Module Fieldbus) as plug-in module for
the
CDM 420
Connection Module.
For connecting one ICR 84x (from firmware version V 1.95) to
DeviceNet
(Slave) via RS 232 data interface.
With shielded 5-pin
M12 plug on front panel for bus connection (enclosure rating max. IP
65) and 5-core terminal strip for connecting 2 digital inputs and 2
digital outputs.
Connection to the CDM 420 via connector, operating temperature
0 to +40
°
C (+32 to +104
°
F), operating voltage
18
to 30 V DC via
CDM 420, power consumption 2 W.
6 029 030
–
Profibus plug, IP 65, for CMF 400-1101
–
Table 10-8: Accessories: Extensions for connection modules CDB 420/CDM 420