When accessing the SensorHub Channel via the SPI PIPE, the first four bits of the sta‐
tus buffer (0101) show a different value for each transaction, in order to check the cor‐
rect function of the interface.
5.2.1
SPI-PIPE timing
The time sequence for SPI PIPE is shown in the time sequence diagram (
below and in
.
spipipe_clk
spipipe_miso
POL=0
PHA=1
1
2
3
4
5
6
7
8
a
b
c
n-1
n
d
e
f
spipipe_ss
Figure 10: SPI-PIPE interface time control
Table 12: SPI-PIPE time control
Diagram
reference
Description
Mini‐
mum
Maxi‐
mum
Units
A
Assertion of
spipipe_ss
before
spipipe_clk
30
ns
B
Time for
spipipe_clk
high
30
ns
C
Time for
spipipe_clk
low
30
ns
D
spipipe_ss
pulse width
30
ns
E
Delay
spipipe_miso
after
spipipe_ss
high
25
70
ns
F
Delay
spipipe_miso
after
spipipe_clk
high
25
70
ns
5.2.2
Read pipeline
The SPI PIPE transaction "Read Pipeline" is used for access to the FIFO buffer values
that contain the data and status of the SensorHub Channel.
Table 13: "Read Pipeline" transaction
Symbol
Meaning
PIPE STATUS
SensorHub Channel status (see
)
PIPE DATA
SensorHub Channel data (see
spipipe_clk
spipipe_miso
PIPE STATUS
PIPE DATA
spipipe_ss
Figure 11: "Read Pipeline" transaction
5.3
Control signals
Various control signals are available between the DSL Master and the frequency
inverter application to configure the performance of the IP Core or to carry out fast
monitoring of the IP Core status.
5.3.1
SYNC signal
sync
is a DSL Master digital input.
5
INTERFACES
24
T E C H N I C A L I N F O R M A T I O N | HIPERFACE DSL
®
8017595/ZTW6/2018-01-15 | SICK
Subject to change without notice