< 0.4 Nm
< 0.55 Nm
< 0.3 Nm
(Force < 30 N)
< 0.8 Nm
< 0.8 Nm
Figure 1: Tightening torque
Note the preferred direction of the object relative to the sensor, cf.
.
Figure 2: Alignment of the sensor relative to the object direction
5
Electrical installation
The sensors must be connected in a voltage-free state. The following information must
be observed, depending on the connection type:
–
Male connector connection: Pin assignment
–
Cable: Wire color
–
Terminal connection: Pin assignment
Terminal connection:
1.
Open the cover.
2.
Swivel the 3/8” MPT (Male Pipe Thread) fitting in the right position horizontally or
vertically.
3.
Loosen 3/8” MPT connection.
4.
Remove sealing plugs.
5.
Lead voltage-free supply cable through.
6.
Connect sensor as per
7.
Retighten 3/8” MPT fitting with seal so that the IP enclosure rating of the device is
ensured.
OPERATING INSTRUCTIONS
26
O P E R A T I N G I N S T R U C T I O N S | GTB20
8026846/2022-06-09 | SICK
Subject to change without notice
en
Summary of Contents for GTB20
Page 2: ...B E T R I E B S A N L E I T U N G GTB20 Kompakt Lichtschranke de en es fr it ja pl pt zh...
Page 38: ...I N S T R U C C I O N E S D E U S O GTB20 Fotoc lulas compactas de en es fr it ja pl pt zh...
Page 92: ...GTB20 de en es fr it ja pl pt zh...
Page 94: ...1 95 2 96 3 97 4 97 5 98 6 102 7 105 8 106 9 106 10 106 94 GTB20 8026846 2022 06 09 SICK ja...
Page 95: ...1 1 1 Product ID pid sick com P N P N CAD EU 1 2 b 1 2 8026846 2022 06 09 SICK GTB20 95 ja...
Page 128: ...M A N U A L D E I N S T R U E S GTB20 Barreiras de luz compactas de en es fr it ja pl pt zh...
Page 146: ...GTB20 de en es fr it ja pl pt zh...
Page 149: ...1 1 1 ID pid sick com P N P N CAD 1 2 b 1 2 2 2 1 8026846 2022 06 09 SICK GTB20 149 zh...