1 2
2
1
1
LED indicator green: supply voltage active
2
Receiver: LED indicator yellow: status of received light beam
5
Mounting
Mount sensors (sender and receiver) using suitable mounting brackets (see the SICK
range of accessories). Align the sender and receiver with each other.
The minimum distance between sender and receiver is:
•
GSE2F(S)-xxx1xx: 24 mm
•
GSE2F(S)-xxx2xx: 72 mm
•
GSE2F(S)-xxx5xx: 238 mm
NOTE
Swap the sender and receiver arrangement at every second through-beam photoelec‐
tric sensor and ensure that there is sufficient distance between the through-beam
photoelectric sensors.
Receiver (GE)
Receiver (GE)
Sender (GS)
Sender (GS)
Sender (GS)
Receiver (GE)
Figure 1: Arrangement of several through-beam photoelectric sensors
Note the sensor's maximum permissible tightening torque of 0.1 Nm.
6
Electrical installation
The sensors must be connected in a voltage-free state (U
V
= 0 V). The following informa‐
tion must be observed, depending on the connection type:
4
OPERATING AND STATUS INDICATORS
6
O P E R A T I N G I N S T R U C T I O N | GSE2 Flat Side
8023329.1C14/28.06.2021 | SICK
Subject to change without notice
en
Summary of Contents for GSE2 Flat Side
Page 62: ...GSE2 Flat Side de en es fr it ja pl pt ru zh...
Page 71: ...10 SICK 10 8023329 1C14 28 06 2021 SICK GSE2 Flat Side 71 ja...
Page 98: ...GSE2 Flat Side de en es fr it ja pl pt ru zh...
Page 106: ...1 120 35 104 3 8 36 C 112 102 9 8 106 GSE2 Flat Side 8023329 1C14 28 06 2021 SICK ru...
Page 107: ...WEEE 10 SICK 10 8023329 1C14 28 06 2021 SICK GSE2 Flat Side 107 ru...
Page 110: ...GSE2 Flat Side de en es fr it ja pl pt ru zh...
Page 119: ...8023329 1C14 28 06 2021 SICK GSE2 Flat Side 119 zh...