7.1
Troubleshooting table
Table 5: Troubleshooting
LED indicator/fault pattern
Cause
Measures
Green LED does not light up
No voltage or voltage below
the limit values
Check the power supply,
check all electrical connec‐
tions (cables and plug connec‐
tions)
Green LED does not light up
Voltage interruptions
Ensure there is a stable power
supply without interruptions
Green LED does not light up
Sensor is faulty
If the power supply is OK,
replace the sensor
Yellow LED flashes
Sensor is still ready for opera‐
tion, but the operating condi‐
tions are not ideal
Check the operating condi‐
tions: Fully align the beam of
light (light spot) with the
object / Clean the optical sur‐
faces / Readjust the sensitiv‐
ity (potentiometer)
Yellow LED lights up, no object
in the path of the beam
Remission capability of the
background is excessive
Check changes to the back‐
ground. Reduce the sensitivity
of the sensor or use sensors
with background suppression
Object is in the path of the
beam, yellow LED does not
light up
Sensitivity is set too low or dis‐
tance between the sensor and
the object is too long
Increase the sensing range,
take note of the distance
between the sensor and the
background
Object is in the path of the
beam, yellow LED does not
light up
Remission capability of the
object is insufficient
Increase the sensing range,
take note of the distance
between the sensor and the
background
8
Disassembly and disposal
The sensor must be disposed of according to the applicable country-specific regula‐
tions. Efforts should be made during the disposal process to recycle the constituent
materials (particularly precious metals).
NOTE
Disposal of batteries, electric and electronic devices
•
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
•
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
•
WEEE:
This symbol on the product, its package or in this document, indi‐
cates that a product is subject to these regulations.
9
Maintenance
SICK sensors are maintenance-free.
We recommend doing the following regularly:
TROUBLESHOOTING
7
8021181.16B5 | SICK
Subject to change without notice
11
Summary of Contents for GRTE18
Page 14: ...B E T R I E B S A N L E I T U N G GRTE18 S V Rundlichtschranken de en es fr it ja pt ru zh...
Page 74: ...GRTE18 S V de en es fr it ja pt ru zh...
Page 82: ...y x 91 3 270 34 67 67 1 35 LED LED 67 82 8021181 16B5 SICK Subject to change without notice...
Page 85: ...GRTE18 S V de en es fr it ja pt ru zh...
Page 95: ...WEEE 79 SICK 79 8021181 16B5 SICK Subject to change without notice 95...
Page 97: ...GRTE18 S V de en es fr it ja pt ru zh...
Page 106: ...44 87 87 1 45 C 87 106 8021181 16B5 SICK Subject to change without notice...
Page 107: ...C 88 WEEE 89 SICK 88 8021181 16B5 SICK Subject to change without notice 107...