7
Commissioning
7.1
Alignment
Align the sensor with a suitable reflector. Select the position so that the red emitted
light beam hits the center of the reflector. The sensor must have a clear view of the
reflector, with no object in the path of the beam [
]. You must ensure that the
optical openings of the sensor and reflector are completely clear.
Figure 2: Alignment
7.2
Check the application conditions
Adjust the distance between the sensor and the reflector according to the correspond‐
ing diagram [
] (x = sensing range, y = operating reserve).
1
0
1
(3.28)
2
(6.56)
3
(9.84)
4
(13.12)
5
(16.40)
6
(19.69)
7
(22.97)
8
(26.25)
100
10
Operating reserve
Distance in m (feet)
x
y
1
2
3
4
5
6
Figure 3: Characteristics
After alignment is complete, move a non-transparent object into the path of the
beam. Use and
to check the function. If the switching output
fails to behave in accordance with the table, check the application conditions,
„Troubleshooting table“, page 9
.