Device type
GLS6
2D code types
Data Matrix ECC200, QR code
Code quality determination
On the basis of ISO/IEC 16022, ISO/IEC 15415, ISO/IEC 15416,
ISO/IEC 18004
Evaluation time
≥ 100 μs
MicroSD memory card
Max. 32 GB
1)
The overspeed is dependent on reading distance, alignment and the 2D code used,
ence values during operation", page 53
.
11.3
Interfaces
Table 16: Technical data: Interfaces
Device type
GLS6
USB
1)
AUX 1 (USB 2.0), for service (e.g. configuration, diagnostics or
image transmission)
CAN
Host 1, 20 kBit/s ... 1 MBit/s
Bus length max. 30 m
Protocols:
•
A connection in a CANopen-based environment is possible. For
additional support, please contact SICK customer service.
•
CSN (SICK CAN sensor network)
Ethernet
Host 2 (10/100 MBit/s) for data output (read result)
Protocols:
•
TCP/IP
•
EtherNet/IP
AUX 2 (10/100 MBit/s), for service (e.g. configuration, diagnostics
or image transmission)
Protocols:
•
TCP/IP
Services: DHCP, NTP, HTTP, mDNS, DNS-SD. DNS and HTTPS.
MAC address (device-specific), see type label
PROFIBUS
Host (RS-232) optionally over external field bus module
CDF600-21xx
2)
to bus (RS-485)
Function blocks for various PLC manufacturers are available online
at:
PROFINET (line topology)
PROFINET Single Port, PROFINET Dual Port (optional over external
fieldbus module CDF600-21xx
2)
)
Function blocks for various PLC manufacturers are available online
at:
EtherCAT
®
Host (RS-232) optionally over external field bus module
CDF600-0300
2)
(gateway mode) to bus (Ethernet)
Digital outputs
4 x physical
V
out
= V
S
– 1.5 V, I
out
≤ 100 mA (typical)
Short-circuit protected, temperature protected, not electrically iso‐
lated from the supply voltage
Optical indicators
5 RGB LEDs (status display) on top of device
1 x LED bar graph display (blue) on top of device
1 x feedback LED (green) as light area on code
1 x RGB LED (status display for memory card), under hinged cover
Acoustic indicator
Beeper (buzzer), can be deactivated
3)
Function for event signaling adjustable
3)
TECHNICAL DATA
11
8024289//2019-08-15 | SICK
O P E R A T I N G I N S T R U C T I O N S | GLS6
49
Subject to change without notice