6.5
Connecting the device
6.5.1
Connecting the supply voltage
Voltage source as per ES1 and PS2 or lower (EN62368-1), or as per SELV (EN60950-1).
The power source for the device must be able to provide the following power outputs:
Table 9: Required supply voltage V
S
Supply voltage V
S
Power source: required power output
1)
DC 12 V ... 24 V ± 20%
Maximum 25 W
1)
For device with 4 loaded digital outputs (each 100 mA).
Table 10: typical current consumption depending on supply voltage
Designation
Supply voltage (V
S
) in [DC V]
9.6
(12 V -20 %)
12
24
28.8
(24 V +20 %)
Current consumption, digi‐
tal outputs unloaded
I
B RMS
[A]
0.4
0.32
0.17
0.14
Power loss, digital outputs
unloaded
P
RMS
[W]
3.84
3.84
4.08
4.03
Maximum current con‐
sumption, digital outputs
unloaded
I
B peak
1)
[A]
1.05
0.90
0.45
0.35
Typical, all 4 digital outputs
loaded (0.1 A per output)
I
B RMS 4Out
[A]
0.8
0.72
0.57
0.54
Power loss, all 4 digital out‐
puts loaded (0.1 A per out‐
put)
P
RMS 4Out
[W]
7.68
8.64
13.68
15.55
1)
For design of the power supply unit, supply cable and fuse protection at the start of the line.
Protecting the supply cables
To ensure protection against short-circuits/overload in the customer’s supply cables,
the wire cross-sections used must be appropriately selected and protected.
The following standards must be observed in Germany:
•
DIN VDE 0100 (part 430)
•
DIN VDE 0298 (part 4) and/or DIN VDE 0891 (part 1)
Connection without connection module
With a supply voltage of DC 12 V to 24 V ± 20%, protect the device with a separate fuse
with value 2 A.
b
Install the fuse in the supply circuit at the start of the supply cable.
6.5.2
Wiring data interfaces
Wiring Ethernet interface
1.
Connect the device to the Ethernet connection of the PC via an adapter cable.
2.
Set up communication via SOPAS ET configuration software.
NOTE
The Ethernet interface of the device has an Auto-MDIX function. This automatically
adjusts the transmission speed as well as any necessary crossover connections.
6
ELECTRICAL INSTALLATION
34
O P E R A T I N G I N S T R U C T I O N S | GLS6
8024289//2019-08-15 | SICK