27
8024019/AE00/V1-0/2019-02| SICK
A D D E N D U M T O O P E R A T I N G I N S T R U C T I O N S | FWE200DH
Subject to change without notice
TECHNICAL DATA
7
7
Technical data
7.1
Optional components
7.2
Spare parts / consumables
Water back purge requirements
Water quality
Drinking water or purified process water (without limescale and solid residues)
Provide a pre-filter if necessary.
Water pressure
Feed with 3…10 barg
Water temperature
Max. 60 °C
Purging pressure
3 barg (min. 2 barg, max. 6 barg)
Water flow rate
Flow rate during purging 5 liters/min
Water requirement
Approx. 5...20 liters per purge process (depending on configuration)
Purging duration
Approx. 3…4 minutes
Purging processes
Standard 3 purges per day (configurable using a control cycle interval)
Power input
Purge air heater
Max. 1 kW
Heated extraction hose
Max. 0.3 kW
Designation
Part No.
Heated extraction hose
230 V, hose 1400 mm, heat sheath 1100 mm
2082195
Heated extraction hose
115 V, hose 1400 mm, heat sheath 1100 mm
2094377
Purge air heater 230 V with accessories for assembly on SLV7 base plate
2105688
Purge air heater 115 V with accessories for assembly on SLV7 base plate
2106812
Designation
Part No.
WBP control block WBP: 2× solenoid valves incl. hose connection and pressure
reducer with filter and base plate
2106005
Hose set: 2 m blue hose
2106006
WBP swirl chamber cover incl. baffle plate
2106007
WBP ball valve connection set; connection for purge air hose at top and bottom
of WBP ball valve (material: PTFE)
2106008
WBP ball valve WBP: Incl. line for control cabinet and 2× solenoid valve plugs
2106071
Water filter
5340636