Installation FLSE100-XT
FLOWSIC100 Flare-XT · Operating Instructions · 8023761/V1-0/2020-10 · © SICK Engineering GmbH
29
5.2.2
Hazard through electrical equipment
5.2.3
Hazards through explosive or ignitable gases
FLSE100-XT sender/receiver units may be used in potentially explosive atmospheres only
according to the respective specifications.
5.2.4
Hazards through electrostatic discharges
The electronic housing of the sender/receiver units and the optionally available spool piece
are painted by the manufacturer with a layer thickness of max. 0.2 mm as standard.
WARNING:
Danger through power voltage
▸
Disconnect power supply lines before working on power connections or
parts carrying power voltage.
▸
Refit any contact protection removed before switching the power voltage
back on again.
WARNING:
Hazards through explosive or ignitable gases
▸
In potentially explosive atmospheres, only use the version of the
FLSE100-XT sender/receiver units specified for such use (
).
▸
during installation work on running
equipment (”hot tapping” method).
WARNING:
Ignition hazard through electrostatic discharge
Ignition hazards through electrostatic discharges exist when FLSE100-XT
sender/receiver units with special paintwork and a layer thickness > 0.2 mm
are used in applications with ignition group IIC according to ATEX and IECEx.
▸
For installation, the risk of electrostatic charging of the surface must be
reduced to a minimum.
▸
Use appropriate caution when performing maintenance and cleaning work.
For example, the surfaces should only be cleaned with a damp cloth. The
respective devices will be identified by the manufacturer with a warning
sign.