EtherNet/IP Gateway
9.10
Description of the data sets
9.10.1
Data sets 1-5
The compilation of data sets 1-5 is fixed; these data sets can only be activated or deactiva-
ted as a whole. The length of these data sets is always the same. The data will be zeroed
for modules that do not exist.
Data set 1
Data set 2
Data set 3
Data set 4
Data set 5
Input data
Output data
Gateway-
specific
diagnostic
data
General
diagnostic
data
Module-specific
diagnostic data
Byte 1
MED1
MQD1
DIG_OUT1
BAS1
MFD1
Byte 2
MED2
MQD2
DIG_OUT2
Backplane
Fault
MFD2
Byte 3
MED3
MQD3
–
CRC1
MFD3
Byte 4
MED4
MQD4
–
CRC2
MFD4
Byte 5
MED5
MQD5
–
–
MFD5
Byte 6
MED6
MQD6
–
–
MFD6
Byte 7
MED7
MQD7
–
–
MFD7
Byte 8
MED8
MQD8
–
–
MFD8
Byte 9
MED9
MQD9
–
–
MFD9
Byte 10
MED10
MQD10
–
–
MFD10
Byte 11
MED11
MQD11
–
–
MFD11
Byte 12
MED12
MQD12
–
–
MFD12
Byte 13
MED13
MQD13
–
–
MFD13
Byte 14
0*
0*
–
–
0*
Byte 15-18
–
–
–
–
MFCLASS1/ CODE1,
MFCLASS2/CODE2 (1)
Byte 19-22
–
–
–
–
MFCLASS1/ CODE1,
MFCLASS2/CODE2 (2)
Byte 23-26
–
–
–
–
MFCLASS1/ CODE1,
MFCLASS2/CODE2 (3)
Byte 27-30
–
–
–
–
MFCLASS1/ CODE1,
MFCLASS2/CODE2 (4)
Byte 31-34
–
–
–
–
MFCLASS1/ CODE1,
MFCLASS2/CODE2 (5)
Byte 35-38
–
–
–
–
MFCLASS1/ CODE1,
MFCLASS2/CODE2 (6)
Byte 39-42
–
–
–
–
MFCLASS1/ CODE1,
MFCLASS2/CODE2 (7)
Byte 43-46
–
–
–
–
MFCLASS1/ CODE1,
MFCLASS2/CODE2 (8)
Tab. 111: Data sets 1–5 of
the UE410-EN