6.4.2.5
“Off” output function
The “Off” output function is only accessible if the “Advanced” user level is activated.
In the “Off” output function, output 2 does not have any function and is therefore
deactivated.
6.4.3
Switching mode for Q
2
(“ModeQ
2
”)
If the output function for Q
2
(“Function Q
2
/Q
a
”) is set to “Switching”, the following
switching modes are available:
■
Distance to object or single switching point (“DtO (1point)”)
■
Switching window (“Window”)
■
Object between sensor and background (“ObSB (Background)”)
■
Shape comparison (“Shape”, Advanced user level only)
■
Fault output (“Alarm”, Advanced user level only)
■
Signal level warning (“SLWarning”, Advanced user level only)
Since this and its function, apart from the designation (Q
2
instead of Q
1
) are absolutely
identical to the switching modes for Q
1
, the following chapters do not provide a new
description. For more details about the switching modes and operating examples for
output Q
2
, refer to the
chapter.
6.4.4
Analog mode for Q
a
(„ModeQ
a
“)
In the factory settings of DT50-2 Pro, output 2 is operated in the “Distance” analog
mode. If the “4-20 mA” or “0-10 V” output function has been selected and the
Advanced user level has been activated, you can choose between “Distance” (
"“Distance” analog mode", page 49
see "“Shape comparison” (“Shape”)
) for the analog mode or the measured value to be output.
6.4.4.1
“Distance” analog mode
6.4.4.1.1
Description
In the “Distance” analog mode, the measured distance value is output as a linearly
proportional current or voltage signal, according to the selected setting for the output
function. Depending on the setting, the analog output behavior for this can be “rising”
or “falling”.
20.5
20.0
4.0
3.5
Min.
Max. distance
mA
2
1
Figure 23: 4-20 mA output function in distance mode with rising output behavior
1
Taught-in or manually set distance for 4 mA
2
Taught-in or manually set distance for 20 mA
OPERATION
6
8017154/1AVV/2021-03-24 | SICK
O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro
49