Operating Instructions
Chapter
9
DME4000
8014584/ZN33/2017-07
© SICK AG • Germany • Subject to change without notice
125
Appendix
9.7.3
Overview of the Hiperface standard status messages
Error type
Status code
Description
Initialization
03H
Table of data field partitioning defect
Log
07H
Transmitter reset via program monitoring
Log
09H
Parity error
Log
0AH
Check sum of the transferred data is false
Log
0BH
Unknown command code
Log
0CH
Number of transferred data is false
Log
0DH
Transferred command argument false
Data
0EH
You may not write in the selected data field
Data
0FH
False access code
Data
10H
You cannot change the size of the entered data field.
Data
11H
Enter work address external to the data field.
Data
12H
Access of non-existent data field
Pre-failure
1EH
Transmitter temperature is critical
See Chapter 8.1, Troubleshooting, for additional error codes.