8.3.12
Defining the active state for service functions
NOTE
The procedure for configuring the Q1 and Q2 digital outputs is identical. The configura‐
tion is illustrated on switching output Q1.
The active state describes the relationship between the switching state (active or
inactive) and the voltage present on the digital output (high or low) (
).
Parameter
Factory setting
LOW:
Output potential for active switching state: low voltage
Output potential for inactive switching state: high voltage
LOW
HIGH:
Output potential for active switching state: high voltage
Output potential for inactive switching state: low voltage
8.3.13
Configuring the QA analog output
Scaling the analog output signal to the distance values (
).
NOTE
The analog output signal is inverted if the distance value for the lower analog output
limit (4 mA) is defined to be larger than the distance value for the upper analog output
limit (20 mA), that means if the output current is reduced as the distance increases.
Parameter
Factory setting
4 mA:
Distance value for lower analog output signal: -4500 m to 4500 m
10 m
20 mA:
Distance value for upper analog output signal:
-4500 m to 4500 m
20 m