0
0
a: 6 %
b: 10 %
c: 18 %
d: 90 %
a
b
c
d
Distance in m (ft)
2
2
(
0.08
)
4
(
0.16
)
6
(
0.24
)
8
(
0.31
)
10
(
0.39
)
12
(
0.47
)
14
(
0.55
)
16
(0.63)
Typ. repeatability in mm (inch)
1
50
(164)
100
(328)
150
(492)
200
(656)
250
(820)
300
(984)
350
(1.148)
400
(1.312)
450
(1.476)
500
(1.641)
550
(1.805)
600
(1.969)
Remission
3
:
Figure 39: DT1000 repeatability with 128 ms measurement cycle time
1
Typical repeatability in mm (inch)
2
Distance in m (ft)
11.1.3
Measurement accuracy diagrams
DL1000 measurement accuracy diagrams
40
30
20
10
0
-10
-20
-30
-40
20
10
0
30
40
50
Distance [m]
2
Accuracy (typical) [mm]
1
60
100
70
80
90
Figure 40: Typical DL1000 measurement accuracy in range
0.2 m … 300 m
1
Accuracy (typical) [mm]
2
Distance [m]
40
30
20
10
0
-10
-20
-30
-40
500
300
100
700
900
1100
Distance [m]
2
Accuracy (typical) [mm]
1
1300 1500
Figure 41: Typical DL1000 measurement accuracy in range
300 m … 1,500 m
1
Accuracy (typical) [mm]
2
Distance [m]
11
TECHNICAL DATA
112
O P E R A T I N G I N S T R U C T I O N S | DT1000 PROFIBUS DP and DL1000 PROFIBUS DP
8024560/1A19/2021-06-30 | SICK
Subject to change without notice