7.2
Overview
Prerequisites
•
Mounting has been completed correctly.
•
Electrical installation has been completed correctly.
Further topics
•
•
•
"Electrical installation", page 33
7.3
Switching on
Overview
After switching on, the sender and receiver initialize. All light emitting diodes of the
sender and receiver briefly light up. After initialization, the receiver displays the align‐
ment quality using four blue light emitting diodes. Once the safety light beam curtain is
aligned (OSSD LED: green), the alignment display switches off after a certain period of
time, and only the PWR LED of the sender and the OSSD LED of the receiver continue
to light up.
In the event of a fault, the red fault LED flashes on the respective device. A red fault
LED in combination with the blue LEDs shows the cause of the fault on the side of the
receiver.
Further topics
•
7.4
Sender and receiver alignment
Overview
After mounting and electrical installation, the sender and receiver must be aligned with
each other.
Important information
DANGER
Dangerous state of the machine
b
Make sure that the dangerous state of the machine is (and remains) switched off
during the alignment process.
b
Make sure that the outputs of the multiple light beam safety device do not affect
the machine during the alignment process.
Further topics
•
"Alignment with the reinforced stainless steel bracket", page 38
•
"Alignment with the stainless steel bracket", page 39
•
"Indication of the alignment quality", page 40
•
COMMISSIONING
7
8021554/14Q7/2020-04-27 | SICK
O P E R A T I N G I N S T R U C T I O N S | deTem2 Core IP69K
37
Subject to change without notice