15.6.3
Change in scanning range using deflector mirrors
Important information
NOTE
The use of deflector mirrors reduces the scanning range depending on the number of
deflector mirrors in the protective field.
Table 86: Scanning range with and without 1 or 2 deflector mirrors
Type
Solution
Scanning
range, typi‐
cal
Scanning range with
1
deflector mirror, typi‐
cal
Scanning range with
2
deflector mirrors, typi‐
cal
PNS75, PNS125
14 mm
20 m
D1 + D2 ≤ 18 m
D1 + D2 + D3 ≤ 16.2 m
PNS75, PNS125
30 mm
30 m
D1 + D2 ≤ 27 m
D1 + D2 + D3 ≤ 24.3 m
Example: Recommended distance when using deflector mirrors
This example assumes a 90° beam deflection per mirror, and a protective field height
of 900 mm.
When using a PNS75 deflector mirror, a distance of D
1
, D
2
, D
3
≤ 4 m between the
deflector mirror and the device, or between 2 mirrors is recommended.
When using a PNS125 deflector mirror, a distance of D
1
, D
2
, D
3
≤ 8 m between the
deflector mirror and the device, or between 2 mirrors is recommended.
D
1
D
2
s
r
D
1
D
2
s
r
D
3
Figure 75: Recommended distance when using deflector mirrors
15.6.4
Deflector mirror PNS75 - ordering information
Table 87: Ordering information for PNS75 deflector mirror
Mirror length in mm
Max. protective field
height in mm
Type code
Part number
340
300
PNS75-034
1019414
490
450
PNS75-049
1019415
640
600
PNS75-064
1019416
790
750
PNS75-079
1019417
940
900
PNS75-094
1019418
1090
1050
PNS75-109
1019419
1240
1200
PNS75-124
1019420
1390
1350
PNS75-139
1019421
1540
1500
PNS75-154
1019422
1690
1650
PNS75-169
1019423
1840
1800
PNS75-184
1019424
1990
1950
PNS75-199
1092962
2140
2100
PNS75-214
1092963
ACCESSORIES
15
8021645/1EB0/2022-04-28 | SICK
O P E R A T I N G I N S T R U C T I O N S | deTec4
161