14.6.3
Change in scanning range using deflector mirrors
Overview
The information relates to 90° beam deflection per mirror and a protective field height
of 900 mm.
Important information
NOTE
The use of deflector mirrors reduces the scanning range depending on the number of
deflector mirrors in the protective field.
Table 32: Scanning range with and without 1 or 2 deflector mirrors
Type
Solution
Scanning
range, typi‐
cal
Scanning range with
1
deflector mirror, typi‐
cal
Scanning range with
2
deflector mirrors, typi‐
cal
PNS75, PNS125
14 mm
8 m
7.2 m
6.4 m
PNS75, PNS125
30 mm
15 m
13.5 m
12 m
14.6.4
Deflector mirror PNS75 - ordering information
Table 33: Ordering information for PNS75 deflector mirror
Mirror length in mm
Max. protective field
height in mm
Type code
Part number
340
300
PNS75-034
1019414
490
450
PNS75-049
1019415
640
600
PNS75-064
1019416
790
750
PNS75-079
1019417
940
900
PNS75-094
1019418
1090
1050
PNS75-109
1019419
1240
1200
PNS75-124
1019420
1390
1350
PNS75-139
1019421
1540
1500
PNS75-154
1019422
1690
1650
PNS75-169
1019423
1840
1800
PNS75-184
1019424
1990
1950
PNS75-199
1092962
2140
2100
PNS75-214
1092963
14.6.5
Deflector mirror PNS125 - ordering information
Table 34: Ordering information, deflector mirror PNS125
Mirror length in mm
Max. protective field
height in mm
Type code
Part number
340
300
PNS125-034
1019425
490
450
PNS125-049
1019426
640
600
PNS125-064
1019427
790
750
PNS125-079
1019428
940
900
PNS125-094
1019429
1090
1050
PNS125-109
1019430
1240
1200
PNS125-124
1019431
14
ACCESSORIES
68
O P E R A T I N G I N S T R U C T I O N S | deTec2 Core
8014276/1DCM/2022-10-27 | SICK
Subject to change without notice