NOTICE
Risk of damaging the device!
Observe the maximum screw-in depth of the blind hole thread. Longer screws than
specified damage the device.
b
Use screws of suitable length.
1.
Prepare the base for mounting the device bracket.
2.
Place the object with the bar code in the view of the device in the position where
the reading is to take place (conveyor static).
3.
Align device with the bar code by sight. When doing so, be aware of the following:
–
Make sure that the device side with the reading window is aligned as near as
possible to parallel to the bar code surface.
–
During reading, note the reading angle that occurs
–
If the position of the bar code within the scanning line is relevant for the eval‐
uation, bear in mind the count direction of the code position
direction of the reading angle and the code angle", page 18
4.
Mount the device bracket onto the base.
5.
Tighten screws through the bracket into the blind tapped holes of the device and
slightly tighten.
MOUNTING
5
8021817/10Y9/2018-09-14 | SICK
O P E R A T I N G I N S T R U C T I O N S | CLV60x
19
Subject to change without notice