Overview of diagrams
Line scanner
Line scanner with oscillating mirror
CLV-Type
Resolution
Scanning method Diagram
Page
CLV 490-0010/-0011 Standard densityLine scanner
Reading field height/resolution as a function of reading distance
CLV 490-0010/-0011 Standard densityLine scanner
Min. and max. reading distance (DOF) for 0.35 mm/40
°
CLV 490-0010/-0011 Standard densityLine scanner
Min. and max. reading distance (DOF) for 0.35 mm/56
°
CLV 490-0010/-0011 Standard densityLine scanner
Min. and max. reading distance (DOF) for 0.50 mm/40
°
CLV 490-0010/-0011 Standard densityLine scanner
Min. and max. reading distance (DOF) for 0.50 mm/56
°
CLV 490-0010/-0011 Standard densityLine scanner
Characteristics field scanning frequency
CLV 490-2010/-2011 High densityLine scanner
Reading field height/resolution as a function of reading distance
CLV 490-2010/-2011 High densityLine scanner
Min. and max. reading distance (DOF) for 0.25 mm/40
°
CLV 490-2010/-2011 High densityLine scanner
Min. and max. reading distance (DOF) for 0.35 mm/40
°
CLV 490-2010/-2011 High densityLine scanner
Min. and max. reading distance (DOF) for 0.35 mm/56
°
CLV 490-2010/-2011 High densityLine scanner
Characteristics field scanning frequency
CLV 490-6010/-6011 Low densityLine scanner
Reading field height/Tilt as a function of reading distance for
0.5 mm
CLV 490-6010/-6011 Low densityLine scanner
Min. and max. reading distance (DOF) for 0.5 mm/40
°
CLV 490-6010/-6011 Low densityLine scanner
Min. and max. reading distance (DOF) for 0.5 mm/60
°
CLV 490-6010/-6011 Low densityLine scanner
Characteristics field scanning frequency
Table 10-2: Overview of specification diagrams for the line scanner
CLV-Type
Resolution
Scanning method
Diagram
Page
CLV 490-1010/-1011 Standard densityL.s. with osci. mirror
Reading field height/resolution as a function of reading
distance
CLV 490-1010/-1011 Standard densityL.s. with osci. mirror
Min. and max. reading distance (DOF) for 0.35 mm/40
°
CLV 490-1010/-1011 Standard density L.s. with osci. mirror
Min. and max. reading distance (DOF) for 0.35 mm/50
°
CLV 490-1010/-1011 Standard densityL.s. with osci. mirror
Min. and max. reading distance (DOF) for 0.50 mm/40
°
CLV 490-1010/-1011 Standard densityL.s. with osci. mirror
Min. and max. reading distance (DOF) for 0.50 mm/50
°
CLV 490-1010/-1011 Standard densityL.s. with osci. mirror
Characteristics field scanning frequency
CLV 490-1010/-1011 Standard densityL.s. with osci. mirror
Deflection range
CLV 490-3010/-3011 High densityL.s. with osci. mirror
Reading field height/resolution as a function of reading
distance
CLV 490-3010/-3011 High densityL.s. with osci. mirror
Min. and max. reading distance (DOF) for 0.25 mm/40
°
CLV 490-3010/-3011 High densityL.s. with osci. mirror
Min. and max. reading distance (DOF) for 0.35 mm/40
°
CLV 490-3010/-3011 High densityL.s. with osci. mirror
Min. and max. reading distance (DOF) for 0.35 mm/50
°
CLV 490-3010/-3011 High densityL.s. with osci. mirror
Characteristics field scanning frequency
CLV 490-3010/-3011 High densityL.s. with osci. mirror
Deflection range
CLV 490-7010/-7011 Low densityL.s. with osci. mirror
Reading field height/Tilt as a function of reading distance for
0.5 mm
CLV 490-7010/-7011 Low densityL.s. with osci. mirror
Min. and max. reading distance (DOF) for 0.5 mm/40
°
CLV 490-7010/-7011 Low densityL.s. with osci. mirror
Min. and max. reading distance (DOF) for 0.5 mm/50
°
CLV 490-7010/-7011 Low densityL.s. with osci. mirror
Characteristics field scanning frequency
CLV 490-7010/-7011 Low densityL.s. with osci. mirror
Deflection range
Table 10-3: Overview of specification diagrams for the line scanner with oscillating mirror