Technical data
9.2
Data sheet CLV 490-1010/-3010/-7010 bar code scanner
Technical data as CLV 490-0010/-2010/-6010 with the following exceptions:
9.3
Data sheet CLV 490-0011 /-2011/-6011 bar code scanner
Technical data as CLV 490-0010/-2010/-6010 with the following exceptions:
Enclosure rating/protection class
IP 65
3)
(to DIN 40 050)/class 3(to VDE 0106/IEC 1010-1)
EMC/vibration/shock tested
to EN 50081-1, 50082-2/IEC 68-2-6 Test FC/to IEC 68-2-27 Test EA
Weight
approx. 1.5 kg
Ambient operating/storage temperature
0 ... +40
°
C/–20 ... +70
°
C
Max. rel. humidity90 %, non condensing
3) With plug cover or plug cover with parameter memory
Type
CLV 490-0010
(Standard density)
CLV 490-2010
(High density)
CLV 490-6010
(Low density)
Table 9-1: Technical specifications of the CLV 490-0010/-2010/-6010
Type
CLV 490-1010
(Standard density)
CLV 490-3010
(High density)
CLV 490-7010
(Low density)
Design
line scanner with oscillating mirror
Reading window
side
Angle of emergence
105
°
(center position CW = 50)
Trigger source for focus control
also: oscillating mirror reversal points
Useful aperture angle
max. 50
°
Oscillating mirror functions
permanent (variable position)/oscillating (amplitude per DC variable or fixed)/One-Shot
1)
Oscillating frequency0.2 ... 4 Hz
Max. angle of deflection
max.
±
20
°
(
±
40 CW), (set with software)
Reading ranges
see
see
Deflection ranges
see
see
see
Operating voltage/power consumption
18 ... 30 V DC/ typically 9 W, max 18 W
Weight
approx. 2.2 kg
1)
One-Shot: one-off oscillating movement per reading pulse (start position and velocity can be selected for forward and return phase)
Table 9-2: Technical specifications of the CLV 490-1010/-3010/-7010
Type
CLV 490-0011
(Standard density)
CLV 490-2011
(High density)
CLV 490-6011
(Low density)
Design
line scanner with heater
Switching on function/temperature graph
see
Chapter 10.4 Optional heating, Page 10-38
Power-on delay35 ... 40 min (at 24 V DC and min. ambient operating temperature –35
°
C)
Operating voltage
24 V DC +20 %/–10 %
Power consumption
typically 75 W, max 90 W
Required cross-section
min. 0.5 mm
2
(for power supply)
Weight
approx. 1.5 kg
Ambient operating/storage temperature
–35 ... +35
°
C/–20 ... +70
°
C
Table 9-3: Technical specifications of the CLV 490-0011/-2011/-6011