Operating Instructions
Chapter
10
CLV 45x Bar Code Scanner
Appendix
8 009 139/K949/06-06-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
10-33
bar codes are explained in
. The functions of the individual parameters are ex-
plained in the "CLV-Setup Help" online help.
10.6
Configuring the CLV with command strings
The CLV can be parameterized and operated with command strings via the terminal inter-
face and the host interface. Parameters that are not recognized by CLV-Setup can also be
used by following the conventions for command strings. This enables special devices, for
example, to be parameterized and new CLV parameters to be configured which may not be
recognized by the CLV-Setup program if this is older than the software on the CLV. The CLV-
Setup user interface is based on the command language.
The command language accesses the CLV command interpreter directly. It is to be used
with care. The commands sent to the CLV are executed immediately. Parameter values that
have been changed by commands are initially only active in the current parameter set in the
RAM of the CLV. Using a special command, the modified parameter record must also be
copied to the EEPROM so that it can be stored permanently, otherwise the changes will be
lost when the supply voltage is switched off.
Bar code
Function
Profile 1
Default setting of CLV for all parameter values.
Code configuration: All code types, except for Pharmacode, enabled for
evaluation.
Overwrites a code configuration created by Auto Setup!
Profile 2
Only changes the configuration of host interface:
– Data transfer rate: 38 400 bits/s
– Data format: 8 data bits, no parity, 1 stop bit
– Repeat request: None
Profile 3
Only changes the configuration of host interface:
– Activate RS 422/485 interface
– SICK network protocol (standard)
– Data transfer rate: 38 400 bits/s
– Data format: 7 data bits, parity odd, 1 stop bit
– Device number: 99
Profile 4
Only changes the configuration of host interface:
Reading result is output as soon as evaluation criteria are fulfilled
Profile 5
Only changes the configuration of host interface:
– Output of error status "ST" in separator
– Output of CLV: <CR> <LF> in terminator (jumps to start of new line after each
code)
Profile 6
Parameterizes CLV as master in master/slave configuration
– No. of slaves: 1
– Timeout: automatic
Profile 7
As Profile 6, but no. of slaves: 2
Profile 8
Parameterizes CLV as slave in master/slave configuration
Profile 9
Parameterizes CLV for pass-through mode: output of " / " and device number in
header
Profile 10
Starts and ends CLV Auto Setup
Profile 11
No function for CLV 45x
Profile 12
No function for CLV 45x
Table 10-6: Function of the preprinted Profile bar codes on card No. 8 008 085