SICK CDF600-2200 Operating Instructions Manual Download Page 5

8015922/1CC9/2021-07-12 • Subject to change without notice • 

SICK AG

 • 

Waldkirch

 • 

Germany

 • 

www.sick.com

C D F 6 0 0 - 2 2 0 0     |   S I C K

5

3. P1/P2 PROFINET connections 

 

M12 - D / female connector

 

4

3

2

1

Pin

Signal

Function

1

TD

+

2

RD+

R

3

TD–

Sender–

4

RD–

Receiver

Pin assignment of both the 4-pin M12 P1/P2 PROFINET IO female 

connectors (D-coded) 

4. DEVICE connection

10 5

6

1

15

11

Pin

Signal

Function

1

DC 24 V

out

Supply voltage OUT (DC 10 V ... 30 V), 

 

max 2 A

2

TxD (AUX) RS-232, sender

3

RxD (AUX) RS-232, receiver

5

GND

Supply voltage ground

4, 6 ... 9

N. c.

10

CAN H

CAN bus

*)

11

CAN L

CAN bus

*)

12 ... 15

N. c.

*)

 CAN-Bus only with support from ID sensor with CAN interface.

Pin assignment of the 15-pin D-SUB HD female connector DEVICE

Wiring of the “EXT. IN 1” switching input

Ext. In 1

*)

 

GND

 

GND

 

V

S out

3

 

4

 

1

 

V

S

 = DC 10 V ... 30 V

V

in

 

*) V

in

 = max. 32 V

V

S

V

S

6.64 K

3.32 K

CDF600-2200

PNP sensor

Example wiring of the EXT. IN 1 switching input

Features

Description

Switching 

behavior

Power at the input starts the assigned function in 

the ID sensor that supports proxy mode

 

(default: level active high, debounce 10 ms)

Properties

Can be wired, e.g., to PNP output of a trigger sensor

Electrical  

values

Low:  |V

in

| ≤ 2 V; |I

in

| ≤ 0.3 mA

 

High:  6 V ≤ |V

in

| ≤ 32 V; 0.7 mA ≤ |I

in

| ≤ 5 mA

LED "EXT. IN 1"

Low: OFF    High: ON

Specifications of the EXT. IN 1 switching input 

Overview of pin assignments and wire colors (cables)
1. POWER connection (supply voltage)

Cable no. 6036384 (5 m)

M12 - A / female connector

 

4

3

5

2

1

Illustration may differ

Pin

Signal

Function

Wire color

1

DC 24 V

in

Supply voltage IN 

 

(DC 10 V ... 30 V)

Brown

2

CAN L

CAN bus

*)

White

3

DC 0 V

in

Supply voltage ground

Blue

4

CAN H

CAN bus

*)

Black

5

N. c.

Gray

Shield

Metal

*)

 CAN-Bus only with support from ID sensor with CAN interface.

Pin assignment of the 5-pin M12 POWER female connector (A-coded, 

straight) of the cable and wire colors of the open cable end  

Cable no. 6049456

1)

, SPEEDCON (3 m)

M12 - A / 

female connector

 

4

3

5

2

1

Illustration may differ

Pin

Signal

Function

Wire color

1

DC 24 V

in

Supply voltage IN 

 

(DC 10 V ... 30 V)

Brown

2

CAN L

CAN bus

*)

White

3

DC 0 V

in

Supply voltage ground

Blue

4

CAN H

CAN bus

*)

Black

5

N. c.

Gray

Shield

Metal

*)

 CAN-Bus only with support from ID sensor with CAN interface.

Pin assignment of the 5-pin M12 POWER female connector (A-coded, 

90° angle) of the cable and wire colors of the open cable end.

1)  Other lengths: no. 6049455 (1.5 m), no. 6049457 (5 m), 

 

no. 6049458 (10 m)

2. EXTERNAL IN 1 connection (digital switching input)

Cable no. 6026133 (2 m)

4
3

5

2

1

M12 - A / male connector

 

Illustration may differ

Pin

Signal

Function

Wire color

1

DC 24 V

out

Supply voltage OUT

 

(DC 10 V ... 30 V), max. 400 mA

Brown

2

N. c.

White

3

GND

Supply voltage ground

Blue

4

EXT. IN 1

External input 1

Black

5

N. c.

Gray

Pin assignment of the 5-pin M12 male connector EXT. IN1 (A-coded, 

straight) of the cable and wire colors of the open cable end

Technical Specifications

Model name

CDF600-2200 (no. 1062460)

Function

Proxy or gateway for PROFINET IO networks

Supported SICK identification sensors

ID sensors that support proxy mode:

CLV61x FIELDBUS, CLV62x ... 65x, CLV69x bar code scanners

 

Lector

®

620 image-based code reader

 

RFH620 and RFH630 RFID read/write devices (both HF) RFU62x and RFU63x (both UHF)

ID sensors that support gateway mode:

Lector

®

64x and Lector

®

65x image-based code readers

 

IDM1xx and IDM2xx hand-held scanner

Station type

PROFINET IO device

Supported communication modes

Dependent upon sensor type, see 

&

 CDF600-22xx Fieldbus Module Technical Information

 (no. 8015924)

In operating mode 0 (proxy): 

 

CDF600 mode with handshake, CDF600 mode without handshake

In operating mode 2 or 4 (gateway): 

 

CDF600 mode with handshake

PROFINET IO data interface

2-port Ethernet in accordance with IEEE 802.3 (data transmission rate 100 MBit/s, full-duplex transmission, 

2-port switch, auto negotiation, auto crossover). 

 

Maximum data length limited to 4000 bytes by communication mode (fragmentation protocol).

AUX data interface

 

(DEVICE connection)

Serial (RS-232), 57.6 kBd or 9.6 kBd, for data communication with the ID sensor

CAN bus data interface

 

(POWER connection)

Connection of an ID sensor via the fieldbus module as a last participant on on a CAN bus. 

 

10 kBit/s .... 1 MBit/s, CAN sensor network. CAN network in the fieldbus module with termination resistor already 

connected on one side

USB data interface

USB 2.0 for configuration and diagnostics 

Digital switching inputs

1 x V

in

 = max. 32 V, can be wired, e.g., with PNP output of a trigger sensor 

Digital switching outputs

Optical indicators

6 x LED

1)

Parameter cloning

Integrated (configuration data of the connected ID sensor, in proxy mode)

Electrical connections

1 x 15-pin. D-SUB HD female connector (DEVICE), with seal

1 x 5-pin M12 male connector (POWER), A-coded

1 x 5-pin. M12 female connector (EXT. IN 1), A-coded

2 x 4-pin. M12 female connector (P1/P2 PROFINET), D-coded

1 x USB female connector, type micro-B (covered)

2)

Supply voltage IN

DC 10 V ... 30 V, reverse polarity protected.

Voltage range may be restricted by connected ID sensor 

 

 see 

“”, page 2

Power supply unit: SELV according to EN 61010 and Class 2 (UL 1310)

 

Protection of the supply cable with max. 3 A

Supply voltage OUT (DEVICE)

As supply voltage IN, not short-circuit-protected.

Power consumption

< 5 W (no ID sensor connected, switching input "EXT. IN 1" not connected)

Fieldbus module current consumption

Max. 250 mA 

Current flow to ID sensor

2 A, max. (internal fuse, cannot be accessed)

Housing/housing color

Non-varnished cast aluminum, light-blue labeling film (RAL 5012)

Electrical safety

IEC 61010-1:2010 + Cor.:2011 

Enclosure rating

IP 65, acc. to EN 60529:1991-10 + A1:2000-02

3)

Electrical protection class

III

Dimensions

207 mm x 49.5 mm x 40.7 mm (without connected cables)

Weight

360 g

Electromagnetic compatibility (EMC)

Radiated emission: acc. to EN 61000-6-3:2007-01 + A1:2011-03

 

Shock resistance: acc. to EN 61000-6-2:2005-08

Vibration resistance/Shock resistance

Acc. to EN 60068-2-6:2008-02 / acc. to EN 60068-2-27:2009-05

Ambient temperature

Operation: -35°C ... +50°C / Storage: -35°C ... +70 °C

Permissible relative humidity

Max 90 %, non-condensing

Mark of conformity

CE, UL 60950-1 (E244281)

1) Under the two LNK/ACT display windows there are 2 separate LEDs

 

2) Only for configuration and diagnosis.

3)  Under the following conditions:

 

When using a SICK scanner standard connection cable for the ID sensor. M12 male connectors of connected lines

 

are 

clamped and unused connections are equipped with yellow, secured protective caps or plugs.

For detailed technical specifications, see the 

Online data sheet

 on the product site on the web (

www.sick.com/CDF600-2

).

Summary of Contents for CDF600-2200

Page 1: ...ified IP enclosure rating To safeguard the IP 65 enclosure rating in active opera tion the following requirements must be met The side panel over the USB interface and the rotary encoding switch must be screwed tight to the device Connections that are not being used must be fitted with yellow protective caps and plugs which must be screwed tight as on delivery The seal on the D Sub HD female conne...

Page 2: ...ion no 8015924 available on the product site on the web www sick com CDF600 2 for suggested courses of action for eliminating hazards 1 In order to install the desired application wire the fieldbus module as appropriate for the ID sensor type with the help of the optional pre assembled SICK cables as shown in the block diagram The cables are only included as ac cessories in the delivery of the mod...

Page 3: ...the rotary encoding switch after the power supply has been switched on are not applied in data communication initially however the POWER LED flashes cyclically 2 times To apply a change to the operating mode to the fieldbus module restart both the fieldbus module and the ID sen sor In order to do this switch off the supply voltage for the fieldbus module and switch it on again c Configuring the fi...

Page 4: ...sor No communication with PROFINET IO O Green ON Fieldbus module ready following start and initialization Operating mode 0 proxy Communication established with ID sensor that supports proxy mode The fieldbus module is operational Operating mode 2 or 4 gateway The fieldbus module is operational EXT IN1 OFF No power supply to external input 11 O Yellow ON Power supply to external input 11 SF OFF Fie...

Page 5: ...62x and RFU63x both UHF ID sensors that support gateway mode Lector 64x and Lector 65x image based code readers IDM1xx and IDM2xx hand held scanner Station type PROFINET IO device Supported communication modes Dependent upon sensor type see CDF600 22xx Fieldbus Module Technical Information no 8015924 In operating mode 0 proxy CDF600 mode with handshake CDF600 mode without handshake In operating mo...

Page 6: ...dust free no direct sunlight as little vibration as possible storage temperature 35 C to 70 C relative humidity max 90 non condensing Repairs Repair work on the fieldbus modules may only be performed by qualified and authorized service personnel from SICK AG Disassembly and disposal Any fieldbus module which can no longer be used at the end of the product life cycle must be disposed of in an envir...