background image

O P E R AT I N G   I N S T R U C T I O N S |   Bulkscan®

8014829/ZV98/2018-05-07| S I C K

Subject to change without notice

8 5

TECHNICAL DATA

Ambient conditions

Ambient temperature operation

0°C … +55°C

Ambient temperature storage

-25°C … +85°C

Approval

Approval

CE, UL, GL

11.4 

Dimensional drawings 

11.4.1 

Dimensional drawing Bulkscan® LMS511

Connector range

4 x M8x9

4 x M8x9

Area to be 

kept clear

Fig. 57: Dimensional drawing Bulkscan® LMS511 (mm)

Summary of Contents for Bulkscan

Page 1: ...O P E R A T I N G I N S T R U C T I O N S Bulkscan FLOW SENSORS Laser volume flowmeter for the throughput measurement of bulk goods e n...

Page 2: ...his work is protected by copyright All rights reserved by SICK AG Reproduction of this document or parts of this document is only permissible within the limits of the legal de termination of Copyright...

Page 3: ...decommissioning 13 2 6 IP technology 13 3 Product description 14 3 1 Special features of the Bulkscan 14 3 2 Operating principle of the Bulkscan 14 3 2 1 Measurement principle 14 3 3 Application exam...

Page 4: ...scan LM111 with weather protection hood 42 5 4 Removing the sensor 43 6 Electrical installation 44 6 1 Requirements for the electrical installation 44 6 1 1 Avoiding potential differences 44 6 1 2 Sui...

Page 5: ...ng a test measurement 68 8 3 Setting tolerances 68 8 3 1 Tolerance against vibration 69 8 3 2 Tolerance against reflection 69 8 3 3 Optimization for outdoor applications 69 8 3 4 Ignore measurement po...

Page 6: ...ing weather protection hood for Bulkscan LMS111 95 11 4 9 Dimensional drawing analog module BAM100 95 12 Ordering information 96 12 1 Scope of delivery 96 12 2 Accessories 96 13 Appendix 99 13 1 Teleg...

Page 7: ...n charge of servicing and maintaining the device 1 3 Information depth These operating instructions contain information about the Bulkscan on the following topics Product description Mounting Electric...

Page 8: ...respect to the use of a certain function or a technical measure Notes inform you about special aspects of the device Display symbols show the status of the 7 segment display of a sender or receiver C...

Page 9: ...onveyor system Knowledge of the software and hardware environment in the relat ed application Basic knowledge of the Windows operating system used Basic knowledge of data transmission Tab 1 Qualified...

Page 10: ...n of people in the context of the relat ed safety standards for machinery The Bulkscan must not be used in explosion hazard areas Any other use that is not described as correct use is prohibited The u...

Page 11: ...gn on the housing Avertissement laser Le Bulkscan n a pas un avertissement laser au bo tier Um die Einhaltung der Laser klasse 1 zu gew hrleisten ist keine Wartung notwendig No maintenance is necessar...

Page 12: ...ntial equalization currents between the Bulkscan and the peripheral devices can have the following effects Dangerous voltages on the metal housing e g of the Bulkscan Incorrect function or irreparable...

Page 13: ...e operating temperature of the sensor drops below 5 C the Bulkscan LMS511 switches on the heating The sensor then consumes a maximum of 90 W The Bulkscan LMS111 consumes a maximum of 10 W in operation...

Page 14: ...only for Bulkscan LMS511 Monitoring of the conveyor belt edges only for Bulkscan LMS511 Scanning range up to 20 with 3 remission Bulkscan LMS511 Scanning range up to 10 with 3 remission Bulkscan LMS11...

Page 15: ...me and total mass 3 3 Application examples The Bulkscan is suitable for non contact continuous detection of the bulk volume on conveyor belts It can be used for example in the following areas Monitori...

Page 16: ...rror Pay attention to the 7 segment display Slight contamination Clean the front screen Flashing Heavy contamination Clean the front screen Information Check ambient conditions Measurements continue P...

Page 17: ...Status signal with the required Logic for the belt opera tion see 4 12 Digital inputs on page 25 How to set an encoder b b Switch to the Measurement tab b b Set Encoder as the source in the Belt spee...

Page 18: ...ume quota volume per pulse b b Configure the Pulse width Ensure that the duration of the pause between pulses is longer than the cycle time resulting from the scan frequency see 8 4 Monitoring of the...

Page 19: ...the required output b b Select the required Logic b b Define the Lower limit the Upper limit and the associated Hysteresis How to configure the signaling of the volume flow rate on an analog output b...

Page 20: ...ue with the aid of the averaging filter see 4 11 Aver aging filter on page 25 How to configure the calculation of the bulk density b b Switch to the Measurement tab b b Configure the Belt speed see 4...

Page 21: ...itch to the Interfaces tab b b Click on Digital outputs to open the Digital outputs tab see 4 13 Digital outputs on page 26 b b Select the assignment Bulk height for the required digital output b b Se...

Page 22: ...ee 8 3 1 Tolerance against vibration on page 69 Otherwise the sensor outputs the value 0 5 You can smooth the measured value with the aid of the averaging filter see 4 11 Averaging filter on page 25 H...

Page 23: ...value drops below a configurable minimal distance If no bulk material is detected the measured distance to both bulk edges equals the conveyor belt width Pay attention to the correct angular adjustmen...

Page 24: ...left and right from the measurement field These edges are detected when the conveyor belt lies within the configurable detection limits Distance from conveyor belt edge smaller than maximal allowed d...

Page 25: ...d Warning All Conveyor edge left or Conveyor edge right b b Configure the Switching delay if required 4 11 Averaging filter The Bulkscan smooths the measured values for the calculation of the Flow Cen...

Page 26: ...digital outputs When turning the sensor on digital outputs are available after the power up delay When the sensor is in Maintenance mode only the output selected as Contamination output is available...

Page 27: ...ly In practice this behavior is not desirable This is prevented by the configurable Hysteresis From the upper and lower limits and their respective hysteresis upper and lower switch ing limits are cal...

Page 28: ...nput source as Analog value b b Configure the 4 mA point and the 20 mA point according to the represented input variable How to configure the analog outputs b b Switch to the Interfaces tab b b Click...

Page 29: ...host interface permits the configuration of the Bulkscan LMS511 and Bulkscan LMS111 and limited output of measured values The interface parameters are freely configurable Network tab Interfaces Serial...

Page 30: ...faces Serial Serial auxiliary interface USB group To connect the electrical interface see 6 2 5 Mini USB connection of Bullkscan LMS511 on page 49 4 15 4 Serial auxiliary interface on Bulkscan LMS111...

Page 31: ...pendent on the thickness of the mounting bracket used 4 M6 screws for mounting the SICK mounting bracket on the support screw length dependent on the thickness of the support Tool set 5 2 Selecting th...

Page 32: ...heck the tightness of the fixing screws On systems that suffer from heavy vibration prevent the fixing screws from com ing loose using screw locking devices Possible ways of mounting the Bulkscan LMS5...

Page 33: ...racket only in conjunction with mounting bracket 1a or 1b cross wise adjustment possible see 5 3 9 Mounting of Bulkscan LMS111 with mounting kit 2 or 3 on page 41 Mounting kit 3 mounting plate only in...

Page 34: ...mounting kit 1 to mount the Bulkscan LMS511 on a mounting surface wall machine Mounting kit 1 Fixing screws M8 x 9 threaded holes Fig 14 Mounting with mounting kit 1 b b Mount mounting kit 1 on the m...

Page 35: ...The maximum adjustment angle is 11 in both planes Mounting kit 2 Mounting kit 1 Fixing screws M8 x 9 threaded holes Fig 15 Mounting with mounting kit 1 and 2 b b Mount mounting kit 2 on the mounting...

Page 36: ...nsures that mounting kit 2 remains precise ly adjustable crosswise on uneven surfaces Mounting kit 2 Mounting kit 3 Mounting kit 1 Fixing screws M8 x 9 threaded holes Fig 16 Mounting with mounting kit...

Page 37: ...2xx mounting kit as a replacement sensor for a Bulkscan LMS211 LMS221 LMS2xx mounting kit part no 2018303 Mounting bracket part no 2059271 Fig 17 Mounting Bulkscan LMS511 with mounting bracket on an e...

Page 38: ...part no 2018304 Mounting bracket part no 2059271 Fig 18 Mounting with mounting bracket and mast bracket b b Mount the mast bracket hand tight on the round post b b Mount the mounting bracket on the ma...

Page 39: ...rate the reference surface on the rear can be used as the third mounting point 1 M5x8 Fig 19 Direct mounting During mounting observe the dimensional drawings see 11 4 5 Dimensional drawing Bulkscan LM...

Page 40: ...ing kit 1a part no 2034324 Fixing screws Fixing screws Threaded holes M5x8 Mounting kit 1b Fig 21 Mounting with mounting kit 1b part no 2034325 1 Mount mounting kit 1a or 1b on the mounting surface 2...

Page 41: ...pin 4 mm in the central hole on mounting bracket 3 4 Fit mounting kit 2 to mounting kit 3 and mount it using two fixing screws M4 10 5 Then mount the Bulkscan LMS111 on mounting kit 2 with the aid of...

Page 42: ...Bulkscan LMS511in combination with the weather protection hood mounting kit 1 and 2 are required 5 3 11 Mounting of Bulkscan LM111 with weather protection hood To protect the Bulkscan LMS111 from glar...

Page 43: ...od Using the mounting kits for the weather protection hood you can align the Bulkscan LMS111 in two planes The maximum adjustment angle is 22 5 in both planes Weather protection hood Adjustments Adjus...

Page 44: ...see 6 3 Wiring the inputs and outputs to the external components on page 51 6 1 Requirements for the electrical installation 6 1 1 Avoiding potential differences The Bulkscan is connected to the peri...

Page 45: ...nd the peripheral devices can have the following effects Dangerous voltages on the metal housing e g of the Bulkscan Incorrect function or irreparable damage to the devices Damage irreparable damage o...

Page 46: ...ate vicinity 20m with SICK standard cables 1 0 mm I O 0 25 mm 50 m 0 5 mm Data RS 232 2 m 0 25 mm Twisted Pair shielded Max 115 200 baud 3 m Max 57 600 baud 10 m Max 19 299 baud Data RS 422 only valid...

Page 47: ...heating Tab 6 Pin assignment of the Power connection Pre assembled connection cables with flying leads are available as accessories see 12 2 Accessories on page 96 Other connection cables may have di...

Page 48: ...ound digital outputs 3 to 6 8 Gray ENC2 Encoder input 2 9 Red OUT3 Digital output 3 10 Violet OUT4 Digital output 4 11 Gray pink OUT5 Digital output 5 12 Red blue OUT6 Digital output 6 Tab 8 Pin assig...

Page 49: ...cessories see 12 2 Accessories on page 96 1 Digital outputs 1 and 2 The minimum switching time from low to high is 3 ms Other connection cables may have different wire colors 6 2 5 Mini USB connection...

Page 50: ...8 GND IN Ground digital input 1 2 Tab 10 Bulkscan LMS111 Pin assignment of the Data connection M12x8 male plug A coded 6 2 7 Connection of the digital inputs outputs on Bulkscan LMS111 1 2 3 4 5 6 7...

Page 51: ...ed Do not use 2 RXD AUX Receiver RS 232 auxiliary interface 3 GND RS Ground RS 232 4 TxD AUX Transmitter RS 232 auxiliary interface Tab 12 Bulkscan LMS111 Pin assignment of the AUX connection 4 pins M...

Page 52: ...DC Bulkscan LMS511 Bulkscan LMS111 Fig 36 Wiring floating digital inputs The inputs require a switching voltage of at least 11 V For this reason the supply volt age must be at least 11 V 6 3 3 Wiring...

Page 53: ...and IN2 on Bulkscan LMS511 Fig 38 Input circuits IN1 and IN2 6 3 5 Connecting the outputs to a PLC on Bulkscan LMS511 24 V EXT OUT1 OUT2 1 4 3 Bulkscan LMS511 PLC 2 _ Fig 39 Connecting the outputs to...

Page 54: ...an LMS111 Fig 41 Connection of the switching outputs e g OUT1 to a PLC non floating active high PLC 10 K OUT1 R OUT1 A OUT1 B DC 24 V IN Bulkscan LMS111 Fig 42 Connection of the switching outputs e g...

Page 55: ...ctive low 6 3 8 Analog inputs outpus with analog module BAM100 6 3 8 1 Module design Fig 45 module design Do not dismount terminals of the module Order Marking 1 BC9050 bus terminal 2 KL3454 3 analog...

Page 56: ...represent a supply rail within the bus terminal block The power contacts are supplied via termi nals on the Bus Coupler PE power contact The power contact labeled PE can be used as a protective earth...

Page 57: ...acts has no connection to the voltage supply for the BC9050 electronics The spring loaded terminals are designed for wires with cross sections between 0 08 mm2 and 2 5 mm2 The assignment in pairs and...

Page 58: ...ll inputs is connected to the 0 V power contact The 24 V power contact is connected to the terminals in order to enable the connection of 2 wire sensors without external supply The power contacts are...

Page 59: ...ur outputs are 2 wire versions and have a common ground potential The power contacts are con nected through The reference ground of the outputs is the 0 V power contact The LEDs indicate the data exch...

Page 60: ...he configuration in non volatile memory in the sensor Select File Save device file to save the configuration outside the sensor e g to have a backup in case of sensor replacement Resetting the configu...

Page 61: ...ntenance operation Teaching in the reference contour Configuration of all functions and interfaces Save parameters in non volatile memory in the sensor Reset sensor Change all passwords Service Only f...

Page 62: ...word for maintenance As Authorized client you can change all passwords How to configure the device code b b Establish the connection to the sensor b b Log in to the sensor as Authorized client b b On...

Page 63: ...t notice 6 3 CONFIGURATION Frame Telegram Frame Designation STX STX STX STX Length Data CS Length byte 1 1 1 1 4 2 495 1 Description Start of text character Length of the data without CS Binary encode...

Page 64: ...tem parameters see 8 2 Performing a test measurement on page 68 a Setting tolerances see 8 3 Setting tolerances on page 68 b Set the Contamination measurement see 8 4 Monitoring of the contamination d...

Page 65: ...ance mode b b On the Teach in configuration bar set the Angle left negative value and right posi tive value such that the maximum possible conveyor belt width can be detected or Click and drag the lef...

Page 66: ...ollowing successful teach in Green Orange Maintenance In the event of an error Green Orange Maintenance Tab 16 Indicators during teach in b b If the teach in process was not successful Check the ambie...

Page 67: ...figuration bar move the Level compensation slider so that the measured contour blue dots matches the reference contour at the unloaded edge areas of the conveyor belt Positive values 0 to 100 mm lower...

Page 68: ...a test measurement b b Start SOPAS and establish a connection to the sensor b b Log in as Authorized client b b Ensure that hazard free operation is possible and start the full conveyor belt b b On th...

Page 69: ...ss as bulk Stagnant water on the conveyor belt In this case the distance values measured are way outside the reference area In rela tion to the reference area the Bulkscan interprets these values as m...

Page 70: ...below the reference contour to be measured leading to incorrect measurement of the throughput The Ignore measurement points below the reference contour function allows you to correct these incorrect m...

Page 71: ...his reduces the emitted and received energy from the laser beam and thereby the measurement accuracy The Bulkscan has six contamination sensors which monitor contamination during operation You can cho...

Page 72: ...es and outputs measured values at the interface Scan frequency Cycle time 25 Hz 40 0 ms 50 Hz 20 0 ms Tab 19 Configurable scan frequencies for Bulkscan LMS111 Scan frequency Cycle time 35 Hz 28 6 ms 5...

Page 73: ...nter the compensation function directly instead of the reference measurements Requirements for the prevention of measurement errors Bulk height of the good transported at least 200 mm Constant belt sp...

Page 74: ...results in the range where the refe rence measurements were made However expected measurements outside of the reference measurement range could result in a larger deviation Linear compensation functio...

Page 75: ...segment display shows b b Place a defined reference volume on the conveyor belt b b Ensure that hazard free operation is possible b b and start the full conveyor belt b b Wait until the bulk has moved...

Page 76: ...uce this effect by using the anti static plastic cleaner and the SICK lens cloth see 12 2 Accessories on page 96 How to clean the front screen 1 Use a clean soft brush to remove dust from the front sc...

Page 77: ...ible measures Sensor is currently starting For Bulkscan LMS111 P is shown b b Wait until the sensor is ready for operation no display Sensor in measuring mode No error Reference measurement for compen...

Page 78: ...see 8 3 3 Optimization for outdoor applications on page 69 Tab 21 Error and status indicators on the 7 segment display 10 4 Status indication BAM100 Fig 56 status indication LEDs diagnosis of voltage...

Page 79: ...hout notice 7 9 FAULT DIAGNOSIS LEDs diagnosis of SPS LED Ethernet Meaning PLC on PLC running flashing cycle time is exceeded off cycle time exceeded permanently or PLC stopped TC DC on TwinCAT config...

Page 80: ...r of echoes evaluated 5 Performance Power up delay temperature dependent 30 s 60 s Cycle time 13 3 ms 20 0 ms 28 6 ms Averaging filter 0 s 3 600 s Measurement accuracy1 3 1 Under reference conditions...

Page 81: ...for LOW Input capacity Static input current Duty cycle Ti T Input frequency Current load 11 V 3 V 6 mA 2 k 24 V 0 V 1 nF 0 5 50 mA 30 V 5 V 15 mA 100 kHz 100 mA Digital outputs Voltage drop load Maxi...

Page 82: ...mit Heating yes Operating range Distance sensor bulk material 0 5 m 10 m Belt speed 30 m s 30 m s Performance Power up delay temperature dependent 60 s Cycle time 20 ms 40 ms Averaging filter 0 s 3 60...

Page 83: ...LOW Input capacity Static input current Duty cycle Ti T Input frequency Current load 11 V 30 V 6 mA 2 k 24 V 0 V 1 nF 15 mA 0 5 50 mA 30 V 5 V 20 mA 100 kHz 100 mA Digital outputs Voltage drop load M...

Page 84: ...and BAM100 100 m max Analog input 4 x 4 mA 20 mA Internal resistance 85 Ohm Resolution 12 Bit Measurement error 0 3 of final value Surge voltage resistance 30 V DC Total response time Bulkscan and BAM...

Page 85: ...HNICAL DATA Ambient conditions Ambient temperature operation 0 C 55 C Ambient temperature storage 25 C 85 C Approval Approval CE UL GL 11 4 Dimensional drawings 11 4 1 Dimensional drawing Bulkscan LMS...

Page 86: ...ulkscan 8014829 ZV98 2018 05 07 S I C K Subject to change without notice 8 6 TECHNICAL DATA 11 4 2 Dimensional drawings mounting kits only for Bulkscan LMS511 Mounting kit 1 Sensor Fig 58 Dimensional...

Page 87: ...O perating instructions Bulkscan 8014829 ZV98 2018 05 07 S I C K Subject to change without notice 8 7 TECHNICAL DATA Sensor Mounting kit 1 Mounting kit 2 Fig 59 Dimensional drawing mounting kit 2 mm...

Page 88: ...ing instructions Bulkscan 8014829 ZV98 2018 05 07 S I C K Subject to change without notice 8 8 TECHNICAL DATA Sensor Mounting kit 1 Mounting kit 2 Mounting kit 3 Fig 60 Dimensional drawing mounting ki...

Page 89: ...ulkscan LMS511 8014829 ZJ56 2017 02 15 S I C K Subject to change without notice 8 9 TECHNICAL DATA 11 4 3 Dimensional drawing mounting bracket for existing LMS2xx mounting kit only for Bulkscan LMS511...

Page 90: ...ect to change without notice 9 0 TECHNICAL DATA 11 4 4 Dimensional drawing mounting bracket with mast bracket only for Bulkscan LMS511 Mounting bracket part no 2059271 LMS2xx mounting kit part no 2018...

Page 91: ...18 05 07 S I C K Subject to change without notice 9 1 TECHNICAL DATA 11 4 5 Dimensional drawing Bulkscan LMS111 All dimensions in mm 152 115 7 79 3 M5 x 7 5 79 3 105 10 49 10 5 116 23 8 Min 15 Max 200...

Page 92: ...ional drawing mounting kits only for Bulkscan LMS111 73 15 9 4 DIN 74 F5 All dimensions in mm 120 21 9 16 74 7 15 7 49 Fig 64 Dimensional drawing mounting kit 1a part no 2034324 73 15 9 4 DIN 74 F5 Al...

Page 93: ...ange without notice 9 3 TECHNICAL DATA 139 4 19 7 4 130 All dimensions in mm 118 5 19 7 18 78 2 40 7 49 18 33 4 37 7 Fig 66 Dimensional drawing mounting kit 2 part no 2039302 158 8 5 150 All dimension...

Page 94: ...7 Dimensional drawing weather protection hood for Bulkscan LMS511 part no 2063050 216 560 193 52 4 63 120 39 4 197 4 60 5 10 1 2 5 343 325 18 93 69 1 Weather protection hood 2 Bulkscan LMS511 3 Mounti...

Page 95: ...4 8 Dimensional drawing weather protection hood for Bulkscan LMS111 R205 All dimensions in mm 174 6 44 114 40 261 5 347 5 Fig 69 Dimensional drawing weather protection hood 190 part no 2046459 11 4 9...

Page 96: ...20 Ethernet TCP IP interface RJ45 CoLA Communication Analog signals 3 x IN 4 20 mA 4 x OUT 4 20 mA 2073296 Measuring wheel en coder with open cable Measuring wheel DFV60E 22EK01024 Cable 1 5 m 8 pin S...

Page 97: ...solution 0 488 mm Inc 2055227 Incremental encoder with blind hollow shaft Incremental encoder DFS60E BHEK01024 Blind hollow shaft 15 mm Cable 8 wire universal 1 5 m Number of lines 1024 Temperature ra...

Page 98: ...onjunction with mounting kit 1 2015623 2015624 Mounting kit 3 Bulkscan LMS511 Mounting bracket for rear mounting on wall floor or machine adjustable longitudinal and lateral axes only in conjunction w...

Page 99: ...gital inputs see 13 1 10 Digital inputs on page 106 Digital outputs see 13 1 11 Digital outputs on page 106 Reference measurement compensation function see 13 1 12 Reference measure ment compensation...

Page 100: ...pes Length Byte Value range bool_1 1 0 oder 1 uint_8 1 0 255 int_8 1 128 127 uint_16 2 0 65 535 int_16 2 32 768 32 767 uint_32 4 0 4 294 967 295 int_32 4 2 147 483 648 2 147 483 647 float_32 4 1 5 10...

Page 101: ...essMode 1 ETX Request STX sMN BsMaintenance ETX Reply STX sAN BsMaintenance ETX Log out STX sMN Run ETX Reply STX sAN Run 1 ETX The Bulkscan switches to the Maintenance operating mode Write a read onl...

Page 102: ...an bool_1 0 No 1 Yes BsContamination Contamination of the front screen bool_1 0 No 1 Yes 13 1 5 Operating mode Teach in Permissible commands sRN sEN Variable name Description Variable type Value range...

Page 103: ...low Mass flow rate float_32 t h mvVolumeSum Volume sum float_32 m mvMassSum Mass sum float_32 t mvGravity Center of gravity float_32 0 to 1 mvHeight Bulk height float_32 m mvDensity Bulk density float...

Page 104: ...fixed value float_32 0 to 106 t h aiMassFlowMin Mass flow rate 4 mA point float_32 0 to 106 t h aiMassFlowMax Mass flow rate 20 mA point float_32 0 to 106 t h parHeightStrategy Bulk height Strategy u...

Page 105: ...kEdgeDist2WarnLeft Distance to left bulk edge warning float_32 0 12 500 mm parBulkEdgeDist2WarnRight Distance to right bulk edge warning float_32 0 12 500 mm BsBulkEdgeWarningLeft Left bulk edge warni...

Page 106: ...low DI2Logic Switching condition Reset volume sum and mass sum uint_8 0 Rising edge 1 Falling edge 13 1 11 Digital outputs Permissible commands sRN sWN Variable name Description Variable type Value ra...

Page 107: ...h Upper limit float_32 106 to106 t h Lower hysteresis float_32 5 to 95 Upper hysteresis float_32 5 to 95 outHeight Bulk height Parameter Variable type Value range Unit Lower limit float_32 0 20 m Upp...

Page 108: ...asArea2 ccMeasArea3 ccMeasArea4 ccMeasArea5 ccMeasArea6 ccMeasArea7 ccMeasArea8 ccMeasArea9 ccMeasArea10 Measured area reference measurement 1 to 10 float_32 m2 ccRefArea1 ccRefArea2 ccRefArea3 ccRefA...

Page 109: ...ion Variable type Value range Unit ODpwrc Operating data Power up counter uint_32 OPcurtmpdev Device status Current tem perature float_32 C SCdevicestate Device status Operational status uint_8 0 Busy...

Page 110: ...N command without prior log on sFA 3 Unknown variable sWN parFxdSpd 10 sFA 4 Variable value range violated sWN parTeachCycles 10 sFA A Variable is write protected sWN mvVolumeSum 1000 sFA B Invalid co...

Page 111: ...O perating instructions Bulkscan 8014829 ZV98 2018 05 07 S I C K Subject to change without notice 1 1 1 NOTES...

Page 112: ...il support sick jp Malaysia Phone 6 03 8080 7425 E Mail enquiry my sick com Mexico Phone 52 472 748 9451 E Mail mario garcia sick com Netherlands Phone 31 30 2044 000 E Mail info sick nl New Zealand P...

Reviews: