O P E R AT I N G I N S T R U C T I O N S |
Bulkscan LMS511
8014829/ZNC5/2017-06-06|
S I C K
Subject to change without notice
8 5
APPENDIX
Variable name
Description
Variable
type
Value range
Unit
LICencset
Encoder: Direction
uint_8
1: None (ENC1)
2: Over phase
(ENC1, ENC2)
3: Over level
(ENC1, ENC2)
aiBeltSpeedMin
Belt speed (4 mA point)
float_32
–30 to +30
m/s
aiBeltSpeedMax
Belt speed (20 mA point)
float_32
–30 to +30
m/s
parDensitySource
Bulk density: Source
uint_8
0: Fixed value
1: Analog value
2: Measured value
parFixedDensity
Bulk density (fixed value) float_32
0 to 50
t/m³
aiDensityMin
Bulk density (4 mA point)
float_32
0 to 50
t/m³
aiDensityMax
Bulk density (20 mA
point)
float_32
0 to 50
t/m³
parMassFlowSource
Mass flow rate: Source
uint_8
0: Fixed value
1: Analog value
2: Measured value
parFixedMassFlow
Mass flow rate (fixed
value)
float_32
0 to 10
6
t/h
aiMassFlowMin
Mass flow rate (4 mA
point)
float_32
0 to 10
6
t/h
aiMassFlowMax
Mass flow rate (20 mA
point)
float_32
0 to 10
6
t/h
parHeightStrategy
Bulk height: Strategy
uint_8
0: Center point
1: Highest point
parAveragingFlow
Averaging filter: Flow
float_32
0 to 3,600
s
parAveragingGravity
Averaging filter: Center of
gravity
float_32
0 to 3,600
s
parAveragingHeight
Averaging filter: Bulk
height
float_32
0 to 3,600
s
parAveragingEdge-
Distance
Averaging filter (bulk
edge and belt edge)
float_32
0 to 3,600
s
13.1.8
System
Permissible commands:
sRN, sWN
Variable name
Description
Variable type Value range
Unit
parVibrationTolerance
Tolerance against vibration
unit_16
0 to 100
%
parReflectionTolerance
Tolerance against reflection
unit_16
0 to 100
%
parParticleFilter
Optimization for outdoor
applications (measuring
mode)
bool_1
0: Deactivated
1: Active
parInvSpotsToZero
Ignore measurement points
below the reference contour:
Activate
bool_1
0: Deactivated
1: Active
parThreshold2Zero
Ignore measurement points
below the reference contour:
Threshold
uint_32
0 to 10,000