O P E R AT I N G I N S T R U C T I O N S |
Bulkscan LMS511
8014829/ZNC5/2017-06-06|
S I C K
Subject to change without notice
8 3
APPENDIX
13.1.3
Saving the configuration in the non-volatile memory
Following successful configuration, you should save the parameters in the non-volatile
memory.
Permissible commands:
sMN
Method name
Description
mEEwriteall
Save the configuration in non-volatile memory
13.1.4
Device information
Permissible commands:
sRN, sEN
Variable name
Description
Variable type
Value range
BsRefAvailable
Reference contour
available
bool_1
0: No
1: Yes
BsTeachFailed
Teach-in failed
bool_1
0: No
1: Yes
BsTeachReady
Teach-in successful
bool_1
0: No
1: Yes
BsInvalidPoints
Too many invalid
measuring points
within a scan
bool_1
0: No
1: Yes
BsContamination
Contamination of the
front screen
bool_1
0: No
1: Yes
13.1.5
Operating mode/Teach-in
Permissible commands:
sRN, sEN
Variable name Description
Variable type
Value range
Unit
BsState
Operating mode
uint_8
1: Teach-in
2: Measuring mode
3: Maintenance
contourRef
Reference contour
381 x float_32
500 to 20,000
mm
contourMeas
Surface contour of
measured object
381 x float_32
15 to 25,000
mm
Permissible commands:
sRN, sWN
Variable name
Description
Variable
type
Value range
Unit
parAngleLeft
Angle left
float_32
–95 to 0
Degree
parAngleRight
Angle right
float_32
0 to 95
Degree
parTeachDistanceMax
Maximum distance
between sensor and
conveyor belt
float_32
500 to 20,000
mm
parTeachCycles
Number of cycles for
averaging the refer-
ence contour
uint_32 100 to 10,000
Cycles
parTeachOutdoor
Optimization for for
slits or gaps
bool_1
0: Deactivated
1: Active