COMMISSIONING
Optimization for belts with slits and gaps disabled.
Teach-in failed. The 7-segment display shows
Maximum
distance
Fig. 35: Optimization for slits or gaps
How to correct conveyor belt irregularities:
Activate the
Optimization for belts with slits or gaps
checkbox on the
Teach-in
config
-
uration bar
Set the
Maximum distance
so that all invalid measurement points are outside of the
scan radius
Click
Teach-in
8.2
Performing a test measurement
Use the scan view in SOPAS to verify the measured contour and the generated mea-
sured values online.
The scan view depends on the available bandwidth of the chosen connection and is not
output in real-time. For this reason not all measured values are displayed.
How to carry out a test measurement:
Start SOPAS and establish a connection to the sensor.
Log in as
Authorized client
.
Ensure that hazard-free operation is possible and start the full conveyor belt.
On the
Operating mode
configuration bar, click
Measuring mode
to start the mea-
surement.
Compare the
Contour
displayed and the
Measured value
with the value expected.
Check, in particular, whether the volume sum or mass sum measured by the sensor
corresponds to the number of volume quotas or mass quotas signaled on the digital
outputs.
If necessary, correct the configuration of the parameters in the
System
tab
Z
(see "8.3 Setting tolerances“ on page 57).
Z
(see "8.4 Monitoring of the contamination degree“ on page 60).
8.3
Setting tolerances
You can use the tolerances to reduce the effects of vibration, strong reflection on the
bulk, dazzle and other environmental influences on the measured values.
Optimization for belts with slits and gaps enabled.
Teach-in successful. The 7-segment display shows
Maximum
distance
Note