CONFIGURABLE FUNCTIONS
Configure the
Mass quota
(mass per pulse).
Configure the
Pulse width
.
Ensure that the duration of the pause between pulses is longer than the cycle time
resulting from the scan frequency (see "8.4 Monitoring of the contamination degree“ on
4.4
Measurement of volume flow rate
The volume flow rate is the volume transported per unit time.
The sensor calculates the volume flow rate from the measured contour and the belt
speed.
You can smooth the measured value with the aid of the averaging filter (see "4.13 Digi
How to configure the calculation of the volume flow rate:
Switch to the
Measurement
tab.
Configure the
Belt speed
(see "4.1 Setting the belt speed“ on page 16).
Configure the
Flow averaging filter
, if required.
How to configure the signaling of the volume flow rate on a digital output:
Switch to the
Interfaces
tab
Click on
Digital outputs
to open the
Digital outputs
tab (see "4.13 Digital outputs“
Select the assignment
Volume flow rate
for the required output.
Select the required
Logic
.
Define the
Lower limit
, the
Upper limit
and the associated Hysteresis.
How to configure the signaling of the volume flow rate on an analog output:
Switch to the
Interfaces
tab.
Click on
BAM 100
to open the
BAM 100
tab (see "4.14 Analog module BAM100“ on
Select the assignment
Volume flow rate
for the required output.
Define the
4 mA point
and the
20 mA point
.
4.5
Measurement of the mass flow rate
The mass flow rate is the mass transported per unit time.
The sensor calculates the mass flow rate from the measured contour, the bulk density,
and the belt speed.
Alternatively you can set the mass flow rate as a fixed value or an analog value. The
sensor then uses this value instead of the measured value.
You can smooth the measured value with the aid of the averaging filter (see "4.11 Aver
How to configure the calculation of the mass flow rate:
Switch to the
Measurement
tab.
Configure the
Belt speed
(see "4.1 Setting the belt speed“ on page 16).
Configure the
Bulk density
as a
Fixed value
or
Analog value
.
Configure the
Mass flow rate
as a
Calculated value
.
Configure the
Flow averaging filter
, if required.
How to configure the signaling of the mass flow rate on a digital output:
Switch to the
Interfaces
tab.
Note
Note
Note