4.2
Example: situation-dependent cleaning with different intensities
Overview
3
2
1
5
6
5
4
4
Figure 5: Example: situation-dependent cleaning with different intensities (schematic representa‐
tion)
1
Pushbuttons
2
Control systems
3
Safety laser scanners
4
airWiper
5
Valve
6
Compressed air supply
The safety laser scanner with a network connection automatically triggers different
cleaning operations depending on the degree of contamination. The cleaning operation
can also be triggered manually.
The following cleaning operations are available:
•
Two-stage preventive cleaning when a warning field reports a detection or
the safety laser scanner reports a contamination warning. Preventive cleaning
removes water droplets early so that the safety laser scanner does not switch to
the OFF state.
•
Two-stage efficient cleaning when the safety laser scanner reports a contamina‐
tion error. Efficient cleaning removes water droplets when the safety laser scanner
has already switched to the OFF state.
•
System cleaning when manually requested using a pushbutton. System cleaning
removes condensate from the compressed air lines and airWiper, e.g., after a long
downtime.
Prerequisites
Parts needed:
•
Compressed air source
•
Compressed air lines
•
Compressed air valves
•
Control systems
•
Pushbuttons
•
Electrical cables