Chapter
3
Operating Instructions
AFS60/AFM60 EtherNet/IP
26
Product description
Instance
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Not used
1
Not used
2
Not used
3
Not used
4
Counts (steps) per revolution CPR (least significant byte)
5
CPR
6
CPR
7
CPR (most significant byte)
8
Total resolution CMR (least significant byte)
9
CMR
10
CMR
11
CMR (most significant byte)
12
Not used
cw/
ccw
13
Not used
scf
14
Not used
raf
15
Not used
16
Nominator for the number of revolutions CNR_N
(least significant byte)
17
CNR_N
18
CNR_N
19
CNR_N (most significant byte)
20
Divisor for the number of revolutions CNR_D
(least significant byte)
21
CNR_D
22
CNR_D
23
CNR_D (most significant byte)
24
Velocity measuring unit (least significant byte)
25
Velocity measuring unit (most significant byte)
26
Not used
100
27
Not used
The structure of the configuration assembly is fixed.
During the initialization of the encoder, it reads the data from the control system.
The “Heartbeat connection point” for input connections of the PLC, i.e. for the encoder
output, must be set to 198 (see Fig. 28 on page 45).
The “Heartbeat connection point” for listen-only connections must be set to 199.
1)
cw = clockwise.
ccw = counterclockwise.
2)
scf = scaling function.
3)
raf = round axis functionality.
Tab. 15: Data format for the
attributes for the configura-
tion assembly