Operating the Sensor
26
© SICK AG • Subject to change without notice. • 8017035/ZMO9/2017-06-08
Setting item
Bank Setting value/
default value
General description
Scaling
Y
Expand or shrink the display range.
*1
Display at 100% size. The whole
range will be displayed.
*2
Display at 200% size.
*4
Display at 400% size.
*8
Display at 800% size.
*16
Display at 1600% size.
*32
Display at 3200% size.
H scroll
Y
—
Move the display position horizontally.
V scroll
Y
—
Move the display position vertically.
Camera/
Area setting
—
Switch to the setting screen.
Graph/
Calc setting
—
Switch to the calculation setting screen. The measured
result will be displayed as a graph.
Output
—
Switch to the output display/setting screen.
5.2.2
Input/Trigger
Set the operation of the input terminals and of the camera start trigger.
Setting
item
Bank Setting value/
default value
General description
IN1
N
Set the behavior of external input terminal IN1.
BANK1
IN1 is used as the first bit for switching banks.
Reset
IN1 is used as the reset input terminal.
IN2
N
Set the behavior of external input terminal IN2.
BANK2
IN2 is used as the second bit for switching banks.
Hold
IN2 is used as the hold input terminal.
IN3
N
Set the behavior of external input terminal IN3.
BANK3
IN3 is used as the third bit for switching banks.
Trigger
IN3 is used as the trigger input terminal.
IN4
N
Set the behavior of external input terminal IN4.
Offset
IN4 is used as offset input.
LaserOFF
IN4 is used as the laser emission stop input.
Reset
—
Execute the reset operation.
Wait...