The factory setting for the switching outputs is Q. The switching behavior can be found
in
Table 4: Push-pull
Q
Push-pull
(
≤
100 mA)
+ (L+)
Q
‒ (M)
+ (L+)
Q
‒ (M)
Q
Push-pull
(
≤
100 mA)
+ (L+)
Q
‒ (M)
+ (L+)
Q
‒ (M)
Important information
NOTE
If IO-Link is used on the device, the MF switching output with the factory setting Q must
be used.
If no IO-Link is used on the device, any of the switching outputs with the factory setting
Q can be used.
The single-beam photoelectric safety switch must not be supplied with voltage via the
IO-Link master.
4.4.2
Test input
Overview
The sender has a test input that can be used to switch off the light beam of the sender
and thereby simulate an interruption of the light beam.
The test input is provided for the purposes of checking the functioning of the sender
and receiver. When used in combination with an external test device to evaluate the
test results, the protective device is suitable for safety applications.
Functionality
As soon as the test input is activated, the light beam of the sender is switched off to
simulate an object having been detected.
b
Refer to
to check the function.
b
If the switching output fails to behave in accordance with
, check the appli‐
cation conditions.
4
PROJECT PLANNING
18
O P E R A T I N G I N S T R U C T I O N S | L25