If a background has not yet been taught in, the user can do this by pressing the
Teach
Background
button. The teach-in process lasts 1.4 seconds. Alternatively, the back‐
ground can be taught in by pressing the teach-in pushbutton on the device. In this case,
the teach-in process is not started until a time delay of 5 seconds has passed. This
makes it possible for people to leave the measuring range and not be incorrectly taught
in as background.
If a background is available, the scan view changes and the live information appears on
the right side of the working range.
A taught-in background is saved directly on the device and is automatically loaded
when the device is restarted.
7.6
Main
The main device settings are made in this menu.
The availability of this menu depends on the selected user level,
.
Basic parameters
Function
Description
Min. distance between
persons [mm]
Input of the permitted minimum distance between several people (fac‐
tory setting 1.5 m). If the permissible minimum distance is undercut,
the respective status display changes from green to red and switching
output OUT1 activates.
Max. number of persons
Input of the total number of people permitted in the region of interest
(factory setting 10 people). If the maximum number of people is under‐
cut, the respective status display changes from green to red and switch‐
ing output OUT2 activates.
Teach Background
Teach in the background (again). It is saved automatically. The previ‐
ously saved background is overwritten in the process.
Delete Background
Deletion of the taught-in background. This is helpful for (re-)alignment
of the device, for example when ambient conditions have changed.
The
Load
function is used to display the background again, also after a
device restart. Complete deletion can only be done in combination with
the
Save Permanently
function.
Lock device button
If selected, the pushbutton is locked on the front side of the device
(repeated) teach-in of the background.
Show Background
If selected, the taught-in background data is shown in the scan view.
Region of interest
Counting people and their distance is only done in the defined region of interest.
Function
Description
X Range [mm]
Using the slider or the input fields, the limits of the detection range can
be adjusted along the longitudinal axis of the device (factory setting
0 m … 8 m). Negative values are also possible due to the scan range of
270°.
Y Range [mm]
Using the slider or the input fields, the limits of the detection range can
be adjusted along the cross-wise axis of the device (factory setting
-6 m … 6 m).
OPERATION
7
8025963//2020-08-05 | SICK
O P E R A T I N G I N S T R U C T I O N S | TiM8xx DistanceGuard
29
Subject to change without notice