6.4.1
TiMxxxA-21xxxxx
“Power/I/O” connection
3
1
7
2
6
5
4
8
9
10
12
11
Table 4: Male connector, M12, 12-pin, A-coded
PIN
Signal
Function
Wire colors connecting
cable part no. 6054974
(5 m), 6054973 (10 m),
6054972 (20 m)
1
1
GND
Ground
Blue
2
DC 9 V ... 28 V
Supply voltage
Brown
3
IN 1
Switching input 1: Reserved
Red
4
IN 2
Switching input 2: Reserved
Green
5
OUT 1
Switching output 1: Minimum dis‐
tance undercut
Pink
6
OUT 2
Switching output 2: Maximum num‐
ber of people exceeded
Yellow
7
OUT 3
Switching output 3: Device over‐
loaded
Black
8
OUT 4
Switching output 4: Reserved
Gray
9
INGND
Common ground for all inputs:
Reserved
White
10
IN 3
Switching input 3: Reserved
Violet
11
IN 4
Switching input 4: Reserved
Gray + pink
12
–
Not wired
Red + blue
–
–
Screen
–
1
Example values when using the specified connecting cable(s). Signal assignment and wire colors can
vary when using other connecting cables.
"Ethernet" connection
1
4
3
2
Table 5: Female connector, 4-pin, D-coded
Contact
Labeling
Description
1
TX+
2
RX+
R
3
TX-
Sender-
4
RX-
Receiver-
6
ELECTRICAL INSTALLATION
24
O P E R A T I N G I N S T R U C T I O N S | TiM8xx DistanceGuard
8025963//2020-08-05 | SICK
Subject to change without notice