PIN
Designation Function
6
nc
Not connected
7
nc
Not connected
8
nc
Not connected
9
Uni-I 11
Universal input 11, configurable:
•
Static control input F1
•
Universal input: sleep mode, restarting the device, pausing
event recording
10
Uni-I 12
Universal input 12, configurable:
•
Static control input F2
•
Universal input: sleep mode, restarting the device, pausing
event recording
11
Uni-I 13
Universal input 13, configurable:
•
Static control input G1
•
Universal input: resetting (OSSD pair 3), sleep mode, restarting
the device, pausing event recording
12
Uni-I 14
Universal input 14, configurable:
•
Static control input G2
•
Universal input: EDM (external device monitoring, OSSD pair
3), sleep mode, restarting the device, pausing event recording
13
Uni-I 15
Universal input 15, configurable:
•
Static control input H1
•
Universal input: resetting (OSSD pair 4), sleep mode, restarting
the device, pausing event recording
14
Uni-I 16
Universal input 16, configurable:
•
Static control input H2
•
Universal input: EDM (external device monitoring, OSSD pair
4), sleep mode, restarting the device, pausing event recording
15
Uni-O 03
Universal output 3: contamination, error, reset required (OSSD pair
3), monitoring result
16
Uni-O 04
Universal output 4: contamination, error, reset required (OSSD pair
4), monitoring result
17
0 V DC
Voltage for inputs and outputs (0 V DC)
1)
1)
If at least one connection of the female connector XG2 is used, this 0 V connection must be connected in
the control cabinet to 0 V DC of the power supply unit using a low-impedance and star-point connection.
8
Replacing the safety laser scanner
If the safety laser scanner is damaged or defective, you must replace it.
DANGER
Hazard due to lack of effectiveness of the protective device
If an unsuitable configuration is saved in the system plug, it may cause the dangerous
state to not end in time.
b
After replacement, make sure the same system plug is used or the configuration is
restored.
b
Make sure that the safety laser scanner is aligned correctly after the replacement.
MOUNTING INSTRUCTIONS
18
M O U N T I N G I N S T R U C T I O N S | microScan3 Pro I/O
8026187/1H7G/2022-10-19 | SICK
Subject to change without notice
en